Connecting the mains cable

Safety

Danger due to work that has been carried out incorrectly.
This can result in serious injury and damage to property.
Danger due to improperly prepared mains cable.
This can cause short circuits and damage.

General

If no mains cable is connected, a mains cable that is suitable for the connection
voltage must be fitted before commissioning.
Strain-relief devices for the following cable cross-sections are fitted to TPS 270i
C power sources:
Power source
TPS 270i C /nc
TPS 270 i C / S/nc
TPS 270i C /MV/nc
Strain-relief devices for other cable cross-sections must be designed accord-
ingly.
Stipulated mains
Power source
cables
TPS 270i C /nc
TPS 270i
C /MV/nc
TPS 270i C /S/nc
**
*
**
62
WARNING!
The work described below must only be carried out by trained and qualified
personnel.
Observe national standards and directives.
CAUTION!
Fit ferrules to all phase conductors and the ground conductor of the
stripped mains cable.
Mains voltage
3 x 380 V
3 x 400 V
3 x 460 V
3 x 200 V
3 x 230 V
3 x 380 V
3 x 400 V
3 x 460 V
3 x 460 V
3 x 575 V
Cable type for USA / Canada: Extra-hard usage
Power source without CE mark; not available in Europe
External diameter of cable
14 - 16 mm
14 - 16 mm
14 - 18.5 mm
Cable cross-section
USA / Canada *
Europe
AWG 14
4G 2.5 mm²
AWG 12
4G 2.5 mm²
AWG 14
4G 2.5 mm²
AWG 14
-