MMA welding

1
IMPORTANT! For optimum welding results, the manufacturer recommends performing an
R/L alignment when starting the device for the first time and when any changes are made
to the welding system.
2
3
An overview of the welding processes is displayed:
-
-
-
-
-
-
-
-
4
The welding voltage is connected to the welding socket with a 3-second time lag.
If the MMA/SMAW welding process is selected, any cooling unit present is automatically
deactivated. It is not possible to switch it on.
5
The MMA welding parameters are shown.
94
CAUTION! Risk of injury and damage from electric shock. As soon as the mains
switch is in the "I" position, the rod electrode in the electrode holder is live. Make
sure that the rod electrode does not touch any persons or electrically conducting
or earthed parts (e.g. the housing, etc.).
Move the mains switch to the "I" position
5
2
Select the "Welding process" button in the left-hand ribbon
Select the "Process" button in the right-hand ribbon
MIG/MAG Pulse-Synergic
MIG/MAG Standard-Synergic
MIG/MAG PMC (option)
MIG/MAG LSC (option)
MIG/MAG Standard-Manual
MMA/SMAW
TIG
Job mode
Select MMA/SMAW welding process
NOTE! Parameters that have been set on a system component control panel
(e.g. wire feed unit or remote control) might not be able to be changed on the pow-
er source control panel.
Select "MMA/SMAW welding" in the left-hand ribbon