Connecting the Mains Cable
Safety
Danger from work that is not carried out properly.
This can result in severe personal injury and damage to property.
▶
▶
Danger from improperly prepared mains cable.
Short circuits and damage to property may result.
▶
General
A strain-relief device for the following cable cross-sections is fitted to the power
source:
Power source
TSt 2700c MP
TSt 3500c MP
*)
Strain-relief devices for other cable cross-sections must be designed accord-
ingly.
Stipulated Grid
Power source
Cables and
Strain-Relief
Devices
TSt 2700c MP
TSt 2700c MP
TSt 2700c MP
TSt 2700c MP
TSt 2700c MP
TSt 2700c MP
TSt 3500c MP
*)
The item numbers of the different cables can be found in the Spare Parts List.
WARNING!
The work described below may only be performed by trained specialist per-
sonnel.
Follow national standards and guidelines.
CAUTION!
Fit ferrules to all phase conductors and the ground conductor of the
stripped mains cable.
Cable cross-section
Canada / US
AWG 14 to AWG 6 *)
AWG 12 *)
Canada / US cable type: Extra-hard usage
Grid voltage
1 x 230 / 240 V
1 x 240 V
1 x 240 V
3 x 200 V
3 x 230 / 240 V
3 x 380 / 400 V
3 x 460 V
3 x 380 / 400 V
3 x 460 V
Canada / US cable type: Extra-hard usage
Europe
4G2.5
4G2.5
Cable cross-sec-
tion
Europe
Canada / US
AWG 14 (15 A) *)
3G2.5 (16 A)
AWG 12 (20 A) *)
-
AWG 12 (30 A) *)
-
AWG 12
4G2.5
AWG 14
4G2.5
AWG 14 *)
4G2.5
AWG 14 *)
4G2.5
AWG 12 *)
4G2.5
AWG 12 *)
4G2.5
51