Connecting the mains cable

Safety

Danger due to work that has been carried out incorrectly.
This can result in serious injury and damage to property.
Danger due to improperly prepared mains cable.
This can cause short circuits and damage.

General

If no mains cable is connected, a mains cable that is suitable for the connection
voltage must be fitted before commissioning.
A strain-relief device for the following cable cross-sections is fitted to the power
source:
Power source
TSt 3500 Syn
TSt 5000 Syn
TSt 3500 MV Syn
TSt 5000 MV Syn
*)
Strain-relief devices for other cable cross-sections must be designed accord-
ingly.
Stipulated mains
Power source
cables and
strain-relief
devices
TSt 3500 Syn
TSt 5000 Syn
TSt 3500 MV
Syn
44
WARNING!
The work described below must only be carried out by trained and qualified
personnel.
Observe national standards and directives.
CAUTION!
Fit ferrules to all phase conductors and the ground conductor of the
stripped mains cable.
Canada / US cable type: Extra-hard usage
Mains voltage
3 x 380 / 400 V
3 x 460 V
3 x 380 / 400 V
3 x 460 V
3 x 208 / 230 / 400 / 460
V
Cable cross-section
fitted strain-relief device
for
Canada / US
AWG 12 *)
AWG 10 *)
AWG 10 *)
AWG 6 *)
Cable cross-sec-
tion
Canada / US
AWG 12 *)
AWG 12 *)
AWG 8 *)
AWG 10 *)
AWG 10 *)
Europe
4G2.5
4G4
4G4
4G10
Europe
4G2.5
4G2.5
4G4
4G4
4G4