Process Parameters For Components - Fronius TPS 320i Operating Instructions Manual

Mig/mag power source
Table of Contents

Advertisement

Process parame-
The following process parameters can be set and displayed for the system components of
ters for compo-
a welding system:
nents
Cooling unit mode
to determine whether a cooling unit is to be switched on or off, or operated automatically
Setting range
Factory setting
Flow watchdog filter time
for setting the time from when the flow watchdog responds until a warning message is
output
Unit
Setting range
Factory setting
Feeder inching speed
for setting the wire feed speed at which the wire electrode is threaded into the torch hose-
pack
Unit
Setting range
Factory setting
TouchSensing sensitivity
for setting the TouchSensing sensitivity for various component surfaces and external in-
fluences
(TouchSensing = detection of the weld seam position using sensor voltage applied during
automated welding)
Unit
Setting range
Factory setting
1
10
TouchSensing only works if the relevant option is available in the power source.
Ignition time out
Length of wire that is fed before the safety cut-out trips
Unit
Setting range
Factory setting
114
eco / auto / on / off (depending on the cooling unit)
auto
s
5 - 25
5
m/min (ipm)
min. - max. (depending on wire-feed unit)
-
-
1 - 10
1
for bare surfaces, robust and not susceptible to interference
for oxidised surfaces, higher measurement-related susceptibili-
ty to interference
mm (in.)
off / 5 - 100 (0.2 - 3.94)
off
NOTE! The "Ignition time out" process parameter is a safety function. The length
of wire that is fed before the safety cut-out trips may differ from the preset wire
length, particularly when the wire is being fed at fast wire feed speeds.