TPS 400i /nc

Mains voltage (U
Max. effective primary current (I
Max. primary current (I
Mains fuse protection
Mains voltage tolerance
Mains frequency
Cos phi (1)
Max. permissible mains impedance Z
PCC
Recommended earth-leakage circuit breaker
Welding current range (I
MIG/MAG
TIG
Rod electrode
Welding current at
U
1
Output voltage range according to standard characteristic
(U
2
MIG/MAG
TIG
Rod electrode
Open circuit voltage (U
Degree of protection
Type of cooling
Overvoltage category
Pollution level according to IEC60664
EMC device class
Safety symbols
Dimensions l x w x h
Weight
Max. noise emission (LWA)
1)
2)
)
1
)
1max
1)
)
2
10 min/40 °C (104 °F)
= 380 - 460 V
)
peak / U
0
Interface to a 230/400 V, 50 Hz public grid
An emission class A device is not designed for use in residential areas supplied
with power from a public low-voltage grid.
The electromagnetic compatibility can be influenced by conducted or radiated ra-
dio frequencies.
3 x
)
1eff
on
max
r.m.s)
0
380 V
400 V
460 V
16.5 A
15.9 A
14.6 A
26.1 A
25.1 A
23.5 A
35 A slow-blow
+/- 15%
50/60 Hz
0.99
92 mOhm
Type B
3 - 400 A
3 - 400 A
10 - 400 A
40%
60%
100%
400 A
360 A
320 A
14.2 - 34.0 V
10.1 - 26.0 V
20.4 - 36.0 V
83 V
IP 23
AF
III
3
2)
A
S, CE, CSA
706 x 300 x 510 mm
27.8 x 11.8 x 20.1 in.
35.2 kg
77.6 lb.
74 dB (A)