7-3. Glossary

A
Accumulated load switching frequency
Allowable Beams
Allowable delay time
Auto reset mode
Auxiliary output
B
Blanking zone
C
Configuration Tool
D
Designated beam output
Designated beam output information
Dynamic muting
E
Effective aperture angle (EAA)
Excess power-on time information
Exit-only muting delay time
Exit-only muting mode
External device monitoring function (EDM)
External test
F
Fixed blanking
Fixed blanking monitoring function
Floating blanking
Floating blanking monitoring function
I
Interlock
Interlock Information
F3SG-R
228
User's Manual
Term
Total number of operations of a load to be connected to the F3SG-RA, from
when the F3SG-RA is first energized until the present time.
Dynamic Muting: Area(s) (or beam(s)) to be added in a Dynamic Muting zone,
in order to prevent an accidental interruption of the F3SG-RA due to vibration.
Fixed/Floating Blanking: Beam(s) in a Blanking zone, that are not monitored by
the Blanking Monitoring function.
The allowable amount of time difference from when the state of the Safety
outputs changes until the state of an external relay changes. The F3SG-R
enters the Lockout state if this time is exceeded.
Mode that disables Start Interlock and Restart Interlock. The Safety outputs are
turned ON when no object is detected in the detection zone.
Function to give output signal according to the settings. This must not be used
for safety applications.
Area in the detection zone of the F3SG-RA, where the Fixed Blanking or the
Floating Blanking is enabled.
Setting tool that allows the user to make settings to the F3SG-RA with a PC.
Function to signal the state of user-designated beam(s) to the Auxiliary output
or Lamp. To use the function, target beam(s) must be designated.
Information on the beam state of user-designated beam(s) to be signaled to the
Auxiliary output or Lamp. To signal the information, the Designated beam
output information must be assigned to an output destination.
Function to configure a new muting zone after muting is enabled based on a
result measuring a workpiece height for a certain period of time.
Range of angles in which the F3SG-R can operate.
Information to be signaled to the Auxiliary output or Lamp when the power-on
time exceeds the power-on time threshold value. To signal the information, the
Power-On Time information must be assigned to an output destination.
Time difference from when the signal of Muting input A or B is turned OFF until
the Muting state is cancelled.
Muting mode to be used for such an application where objects move from the
inside to the outside of the hazardous zone.
Function to monitor the operation of an N.C. contacts of external relays (or
contactors) that control the hazardous zone of a machine, for any malfunctions
such as welding.
Function that stops emission at a specified time to check that the Safety
outputs are being properly turned OFF.
Function to disable part of the detection zone of the F3SG-RA and keep the
Safety outputs in the ON state even if an object blocks the disabled detection
zone.
Function to bring the F3SG-RA in the Lockout state when part of the Fixed
Blanking zone is blocked.
Function to disable a specified number of beams in the detection zone of the
F3SG-RA, and keep the Safety outputs in the ON state even if an object
smaller than the dimension of the specified number of beams blocks the F3SG-
RA.
Function to bring the F3SG-RA in the Lockout state if the number of blocked
beams is smaller than specified.
Information to be signaled to the Auxiliary output or Lamp when the F3SG-R is
in the Interlock is state. To signal the information, the Interlock information must
be assigned to an output destination.
Provides output through auxiliary output if interlock input is ON. Note that
interlock information must be assigned to the destination.