Omron F3SG series User Manual page 253

Safety light curtain
Hide thumbs Also See for F3SG series:
Table of Contents

Advertisement

Term
Interlock reset
Inverted signal output mode
L
Light level diagnosis information
Light level monitoring
Load switching frequency
Lockout
Lockout information
Lower beam(s)
M
Maintenance information
Manual reset mode
Maximum allowable muting signal interruption
Muting
Muting end wait time
Muting input time limit value (maximum)
Muting input time limit value (minimum)
Muting key cap
Muting sensor
Muting sequence error
Muting time limit
N
Number of floating beams
O
Object resolution (Detection capability)
Operating range selection
Operating status monitoring
Output operation mode
Override
Override input time limit (maximum)
Override time limit
Cancels the Interlock state.
In this mode, the logic of the Auxiliary output signal is reversed.
Information to be signaled to the Auxiliary output or Lamp when the Safety
output is in the ON state and when the incident light level is from 100% to 170%
of the ON-threshold value for 10 seconds or more. To signal the information,
the Light Level Diagnosis information must be assigned to an output
destination.
Function to read out the light level of incident light or ambient light on the
F3SG-RA.
Function to display the number of operations of a load to be connected to the
F3SG-RA. The number is counted from when the number was last reset until
the present time.
Function to keep the Safety outputs in the OFF state when an error is detected
by the F3SG-R.
Information to be signaled to the Auxiliary output or Lamp when an error or
lockout occurs. To signal the information, the Lockout information must be
assigned to an output destination.
Beams located toward the Power Cable of the F3SG-R.
Function to read the maintenance information of the F3SG-RA and view it on a
PC screen, with the Configuration Tool.
Function to enable the Start Interlock and Restart Interlock. The Safety outputs
are turned ON by applying a reset signal when there is no object in the
detection zone.
Maximum duration of a signal interruption allowed in Muting inputs A and B.
Function to temporarily disable the safety function of the F3SG-RA and keep
the Safety outputs in the ON state even if the F3SG-RA is blocked.
Time difference from when the F3SG-RA is unblocked until the Muting state is
cancelled.
Maximum time difference between Muting inputs A and B.
Minimum time difference between Muting inputs A and B.
Connector to be attached to the end cap of an emitter or receiver to use the
Muting function.
Input device, such as photoelectric sensor or proximity sensor, to give an input
signal for notifying the start and end of the Muting function.
An error that occurs when muting signal is not received in the correct order. The
Safety outputs keep in the ON state unless the F3SG-RA is blocked.
The duration time of the Muting function. The Muting state is cancelled if it
continues for longer than this time limit.
Number of beams to be configured in the Floating Blanking zone, for which the
F3SG-RA does not transition to the Lockout state or Machine Stop state (Safety
output OFF) even when blocked.
Minimum size of an object that can be detected in the protective height of the
F3SG-R.
Function to change the operating range by changing the emission light level of
the F3SG-R.
Function to read out the I/O data and status of functions of the F3SG-RA.
Information to be signaled to an output part (Safety output, Auxiliary output).
Function that forcibly turns the Safety outputs ON when the Muting is not
working.
Input time limit (maximum value) of the special sequence to activate the
Override function.
The duration time of the Override function. The Override state is cancelled if it
continues for longer than this time limit.
Appendix
Description
E
F3SG-R
229
User's Manual