4-5-4. Cable Connections(F3SG-RE Series)

Extension of the cable must be within a specified length. If it isn't, safety function may not
work properly, resulting in danger.
There are no dedicated cables for the F3SG-RE series. You can use the cables that satisfy the
following requirements:
1. Emitter: 4-wire Receiver: 4-wire4
2. 0.3 mm
or larger, conductor resistance 0.058 ohms/m max.
2
Do not use cables in the same conduit as high voltage or electric power lines.

4-5-4-1. Recommended Cable

 Single-Ended Cable (Round Water-resistant Connector: Connector Connected to
Cable, Socket on One Cable End) (XS5F-D421-80-F, sold separately)
40.7
14.9 dia.
M12
Specification
Fire-retardant, Robot cable
 Double-Ended Cable (Round Water-resistant Connector: Connectors Connected to
Cable, Socket and Plug on Cable Ends) (XS5W-D421-81-F, sold separately)
40.7
L (Cable length)
Specification
Fire-retardant, Robot cable
L (Cable length)
6 dia.
Model
XS5F-D421-C80-F
XS5F-D421-D80-F
XS5F-D421-E80-F
XS5F-D421-G80-F
XS5F-D421-J80-F
XS5F-D421-L80-F
6 dia.
44.7
Model
XS5W-D421-C81-F
XS5W-D421-D81-F
XS5W-D421-E81-F
XS5W-D421-G81-F
XS5W-D421-J81-F
XS5W-D421-L81-F
Terminal No.
1
2
3
4
30
5
50
L (m)
1
2
3
5
10
20
Terminal No.
M12
1
2
3
4
L (m)
1
2
3
5
10
20
Wiring/Installation
(Unit: mm)
Cable color of
core sheath
Brown
White
Blue
Black
(Unit: mm)
Cable Color
of core
sheath
Brown
1
White
2
Blue
3
Black
4
F3SG-R