Ratings/Specifications - Omron F3SG series User Manual

Safety light curtain
Hide thumbs Also See for F3SG series:
Table of Contents

Advertisement

1-5. Ratings/Specifications

The  in the model names indicate the protective heights in millimeters.
Type of ESPE
Type 4
(IEC 61496-1)
Type 2
Performance
Object Resolution
(Detection Capability)
Beam Gap
Number of Beams
Lens Size
Protective Height
Long
Operating Range
Short
ON to OFF
OFF to ON 40 to 90 ms *1
Response Time
*1. Response time when used in one segment system or in cascaded connection.
Refer to 1-6. List of Models for more information.
*2. Selectable by Configuration Tool.
Effective Aperture
Type 4
Angle (EAA) (IEC
Type 2
61496-2)
Light Source
Startup Waiting Time
Electrical
Power Supply Voltage (Vs)
Current Consumption
Safety Outputs (OSSD)
Auxiliary Output
Safety
Output
Output Operation
Mode
Auxiliary
Output
F3SG-4RA-14
F3SG-4RA-30
F3SG-2RA-14
F3SG-2RA-30
F3SG-4RA-14/-30
F3SG-2RA-14/-30
Opaque objects
14-mm dia.
30-mm dia.
10 mm
20 mm
15 to 207
8 to 124
5.2 × 3.4 (W × H) mm
7-mm dia.
160 to 2080 mm (6.3 to
190 to 2510 mm (7.3 to
81.9 inch)
98.7 inch)
0.3 to 10.0 m (1 to 32 ft.) 0.3 to 20.0 m (1 to 65 ft.) 0.3 to 10.0 m (1 to 32 ft.) 0.3 to 20.0 m (1 to 65 ft.)
0.3 to 3.0 m (1 to 10 ft.)
0.3 to 7.0 m (1 to 23 ft.)
Normal mode: 8 to 18 ms *1
Slow mode: 16 to 36 ms *1 *2
±2.5° max., emitter and receiver at operating range of 3 m or greater
±5.0° max., emitter and receiver at operating range of 3 m or greater
Infrared LEDs, Wavelength: 870 nm
2 s max.
SELV/PELV 24 VDC±20% (ripple p-p 10% max.)
Refer to 1-6. List of Models
Two PNP or NPN transistor outputs (PNP or NPN
is selectable by DIP Switch.)
Load current of 300 mA max., Residual voltage of 2 V max. (except for voltage drop due to cable
extension), Capacitive load of 1 F max., Inductive load of 2.2 H max. *1
Leakage current of 1 mA max. (PNP), 2 mA max. (NPN) *2
*1. The load inductance is the maximum value when the safety output frequently repeats ON and OFF.
When you use the safety output at 4 Hz or less, the usable load inductance becomes larger.
*2. These values must be taken into consideration when connecting elements including a capacitive
load such as a capacitor.
One PNP or NPN transistor output (PNP or NPN is
selectable by DIP Switch.)
Load current of 100 mA max., Residual voltage of
2 V max .
Light-ON (Safety output is enabled when the receiver receives an emitting signal.)
Muting or Override output (default) (Configurable
by Configuration Tool)
Overview and Specifications
F3SG-4RE14
F3SG-4RE30
F3SG-2RE14
F3SG-2RE30
F3SG-4RE14/30
F3SG-2RE14/30
14-mm dia.
30-mm dia.
10 mm
20 mm
15 to 207
8 to 124
5.2 × 3.4 (W × H) mm
7-mm dia.
160 to 2080 mm (6.3 to
190 to 2510 mm (7.3 to
81.9 inch)
98.7 inch)
0.3 to 3.0 m (1 to 10 ft.)
0.3 to 7.0 m (1 to 23 ft.)
5 to 15 ms
25 to 75 ms
F3SG-REP: Two PNP transistor
outputs
F3SG-REN: Two NPN transistor
outputs
-
-
E
F3SG-R
11
User's Manual

Advertisement

Table of Contents
loading

Table of Contents