2-11. Auxiliary Output

Do not use the auxiliary output for safety applications.
Failure to do so may result in serious injury when the F3SG-RA fails.
F3SG-RA Series
F3SG-RE Series
2-11-1. Overview
The auxiliary output is used to monitor the status of F3SG-RA. This output can be connected to a
device such as an indication lamp, programmable controller, etc.
Usage Example:
• Indicate that F3SG-RA is in muting or override state
• Indicate that a machine is stopped (Safety outputs are in the OFF state)
The Auxiliary Output is not available for the F3SG-RE.
<Basic wiring diagram>
Sh
own below are hard wirings for PNP and NPN types, respectively.
+24 VDC: Brown
AUX: Red
F3SG-R
Receiver
PNP
0 VDC: Blue
The load current of the auxiliary output is 100 mA max.
X
+24 V
Load
0 V
System Operation and Functions
+24 VDC: Brown
F3SG-R
Load
Receiver
NPN
AUX: Red
0 VDC: Blue
+24 V
0 V
E
F3SG-R
41
User's Manual