Overview and Specifications
Location
13
Communication
Bottom-beam-
14
state
*1. The EDM indicator is illuminated when the RESET input is in the ON state regardless of the use of
the EDM function.
*2. Refer to the timing chart of Pre-Reset mode in 2-9. Interlock for more information of blinking patterns.
*3. Muting/Override and cascade connection are not available for the F3SG-RE.
Refer to 7-3. Glossary for definitions of terms used in the table above.
TOP, CFG, LOCKOUT, STB and ON/OFF indicators are illuminated when the receiver of the F3SG-RA is
in Setting mode.
F3SG-R
10
User's Manual
Name of Indicator
Color
COM
Green
BTM
Blue
F3SG-RA
F3SG-RE
Illuminated
Series
Series
Synchronization between
emitter and receiver is
X
X
maintained
The bottom beam is
X
X
unblocked
Blinking
Lockout state due to
Communication error, or
error due to abnormal
power supply or noise
Muting/Override state , or
Lockout state due to DIP
Switch setting error *3

Advertisement