System Operation and Functions
For detection capability on the border between the blanking zone and normal detection zone when
allowable beam is configured, see next table.
Detection capability on the border between the blanking zone and normal detection zone when
allowable beam is specified.
Allowable Beam on One End
Disable
1 beam
2 beams
 F3SG-R LED indicator status
When fixed blanking is being enabled, the blanking indicator turns on.
 Constraint between Fixed Blanking Zones
More than one fixed blanking zone can be configured adjacently (Figures 1 and 2). But allowable
beams cannot be set adjacently (Figure 3). You cannot overlap fixed blanking zones. (Figure 4)
Upper
Lower
Upper
Lower
 Limitation for Combination with Other Functions
You can use this function in combination with muting, floating blanking, and warning zone functions at
the same time with the setting tool for F3SG-R.
F3SG-R
78
User's Manual
F3SG-RA-14
14 (same as nominal)
24
34
Fixed blanking zone 1
Fixed blanking zone 2
Figure 1
Fixed blanking zone 1
(Lower 1 allowable beam)
Fixed blanking zone 2
(Upper 1 allowable beam)
Figure 3
Normal detecting beam
Fixed blanking beam
Allowable beam
[mm]
F3SG-RA-30
30 (same as nominal)
50
-
Upper
Fixed blanking zone 1
(Allowable beam: 1 lower beam)
Fixed blanking zone 2
Lower
Figure 2
Upper
Fixed blanking zone 1
Fixed blanking zone 2
Lower
Figure 4