System Operation and Functions
2-11-2. Factory Default Setting
The factory default setting is Muting/Override Information. When F3SG-RA is under a muting or
override state, the F3SG-RA switches ON and OFF at 0.5 s (1 Hz).
Muting state
Override state
Auxiliary output
2-11-3. Setting with DIP Switch
When the Interlock is set to Pre-Reset Enabled by the DIP Switch, the auxiliary output is configured as
a inverted signal of the safety output. Other settings are configured as the same as the factory default
setting.
Beam state
OSSD
Auxiliary output
F3SG-R
42
User's Manual
ON
OFF
ON
OFF
Switching at every 0.5 s
OFF
Unblocked
Blocked
Toff
ON
OFF
ON
OFF
Ton
Ton: Response time OFF to ON
Toff: Response time ON to OFF