System Operation and Functions
 Timing chart
Muting input A
Muting input B
Muting state
Auxiliary output
Beam state
OSSD
 Default settings
Variable
T
1min
T
1max
T
2
T
3
F3SG-R
48
User's Manual
ON
OFF
T1min to T1max
ON
OFF
80 ms max.
Enabled
Disabled
Blinking
OFF
Unblocked
Blocked
ON
OFF
Variable name
Muting input time limit value
0.1 s
(minimum)
Muting input time limit value
4 s
(maximum)
Muting time limit
60 s
Maximum allowable muting
0.1 s
signal interruption
T3 max.
T3 max.
T2 max.
Blinking at 0.5 s (1 Hz)
Value
Minimum time difference between muting inputs A and B.
If the time difference between muting inputs A and B is smaller
than this value, a muting sequence error occurs.
Maximum time difference between muting inputs A and B.
If the time difference between muting inputs A and B is larger
than this value, a muting sequence error occurs.
The duration time of the Muting function. The Muting state is
cancelled if it continues for longer than this time limit.
Maximum duration of a signal interruption allowed in muting
inputs A and B.
Description