Glossary - Omron F3SJ Series Original Instructions Manual

Safety light curtain
Table of Contents

Advertisement

Appendix

Glossary

Term
A
Access qualification
Accumulated load
switching frequency
Administrator level
Allowable delay time
Auto reset
Auxiliary output 1
Auxiliary output 2
Auxiliary output
diagnosis function
B
Basic system
Blanking zone
Breakage detection
D
Designated beam
interruption information
Designated beam output Provides output based on incidence/interruption status of a designated beam. Destination can be
Detection capability
Disturbance light level
display
E
Effective aperture angle
(EAA)
End beam disable mode If either end beam of the F3SJ is set as a floating beam, its status as a floating beam target is cancelled.
Error/lockout information This information is output from the auxiliary output or external indicator when an error or lockout occurs.
Exit only muting delay
time
Exit only muting mode
External device
monitoring function(EDM)
External indicator
diagnosis function
External Indicator
Output 1
External Indicator
Output 2
External test
F
Fixed blanking
Fixed blanking
monitoring function
Fixed blanking zone
F3SJ-A
196
User's Manual
Function that requires a password to change setting to prevent careless change of F3SJ's functional
setting.
This value indicates the cumulative value for load switching frequency, from when power was first
supplied to the F3SJ until the present.
Mode for F3SJ's functional setting change. Password input is required to log in to this mode because of
access qualification.
The allowable amount of time from when the safety output changes until the external device monitoring
input changes. The F3SJ enters lockout if this time is exceeded.
Setting status by which the safety output automatically turns ON when the F3SJ receives light after the
power is turned ON and after the F3SJ is blocked.
Allows output appropriate for the setting. This CANNOT be used for safety applications.
Allows output appropriate for the setting. This CANNOT be used for safety applications. When a muting
enabling key cap (F39-CN6) is attached, this output is used as a muting input.
Detects breakage and short-circuits for the muting lamp or external indicator connected to auxiliary
output 1.
This refers to the F3SJ in the state it is in when purchased. The basic system provides basic safety light
curtain functions. Most functions can be used without performing additional configuration.
A range of consecutive beams for which fixed or floating blanking is configured.
This function puts the F3SJ in lockout when there is broken connection between the output terminals for
the external indicator.
ON is output when any of the designated beams are interrupted. Beams must be designated if this
output operation is selected.
assigned to auxiliary output or external indicator output.
Minimum size of an object that can be detected in the protective height of the F3SJ.
This display can read out the disturbance light level of the F3SJ. For the PC tool for F3SJ, the level can
be checked using a graph.
Range of angles for which the F3SJ can operate.
Note that the error/lockout information must be assigned to an output destination.
The OFF delay time from when the signal of muting input 1 or 2 turns OFF until the muting state is
cancelled.
Used when there is only enough space to install a muting sensor on one end of the F3SJ.
Function that detects malfunctions, such as welding, in external relays (or contactors) that control the
hazardous zone of a machine, by monitoring the operation of N.C. contact.
Detects breakage and short-circuits for the muting lamp or external indicator connected to the external
indicator output.
Allows configuration of receiver's output based on settings. This CANNOT be used for safety
applications.
Allows configuration of emitter's output based on settings. This CANNOT be used for safety
applications.
Function that stops emission at any time to check that the safety output is being properly turned OFF.
Disables part of F3SJ's operation range. Safety output will not change even if an object enters the
disabled zone.
This function puts the F3SJ in lockout state when part of the fixed blanking zone is interrupted.
This refers to the zone set in the fixed blanking function. One zone can be set by the setting console,
and 5 zones can be set by the PC tool for F3SJ.
Definition