System Operation and Functions
2-12-4. Dynamic Muting
The Dynamic Muting function can configure a new muting zone while the muting state is enabled,
based on a result measuring a workpiece height for a certain period of time.
This materializes safer muting function with a limited muting zone adjusted according to a workpiece
height.
 Usage Example
This function cannot be used for an application in which a workpiece height gets larger after measuring
the zone as shown below.
Application Examples
 Zone Measurement Start Condition
After the muting start condition is satisfied and the full detection zone is muted, interruption of a part of
the F3SG-RA causes the Zone Measurement to start.
 Zone Measurement
The Zone Measurement monitors the highest and lowest parts of a passing workpiece during the
dynamic muting measurement time Tdyn (3 s). (Void spaces in workpiece(s) are ignored.)
 Zone Determination
A zone enclosed by the highest and the lowest parts of the workpiece is set as a new muting zone.
Configuring a dynamic muting allowable beam allows the muting zone to be expanded by the number
of allowable beams. Configuring a dynamic muting allowable beam prevents unintended line stop due
to swing of a workpiece, etc. (The factory default setting of the dynamic muting allowable beam is 1.)
F3SG-R
68
User's Manual
Applicable Example
Position after Zone
Measurement
NOT Applicable Example
Application Examples
Position after Zone
Measurement