 Dynamic Muting Allowable Beam
The dynamic muting allowable beam allows the muting zone measured by the Zone Measurement to
be expanded by the number of additional beam(s) specified as allowable beam.
 Timing chart
Muting Input A
Muting Input B
Enabled
Muting State
Disabled
Unblocked
Beam state
Blocked
Zone Measurement
2-12-5. Factory Default Setting
In the factory default setting, the muting mode is set to Standard Muting Mode and the dynamic muting
to Disable.
2-12-6. Setting with DIP Switch
If the pre-reset function is enabled by the DIP Switch, the muting function is disabled.
Otherwise the muting function is always being enabled.
Refer to Chapter 3 Setting with DIP Switch for more information on setting this function by the DIP Switch.
2-12-7. Setting with Configuration Tool
Some settings of functions configurable with the Configuration Tool may increase risks.
Make sure the Responsible Person conduct a thorough risk assessment analysis before
managing and changing the settings. Unintended changes to the settings may cause a
person to go undetected, resulting in serious injury.
The user can make changes to the settings by the Configuration Tool.
Function
Muting function *
Muting mode
Statistics data recording
*Setting parameters of the following functions are saved according to the states where the Muting function is
enabled and disabled, respectively. After changing the Muting function from Enable to Disable or from Disable to
Enable, also check the settings of these functions again.
Affected functions: External Device Monitoring (EDM), Start Interlock, Restart Interlock, Auxiliary Output, Lamp
Output
ON
OFF
ON
OFF
All Zone
ON
OFF
Tdyn (3 s)
Factory Default Setting
Enable
Standard muting mode
Enable
System Operation and Functions
Partial Zone
Available Parameters
Enable/Disable
Standard muting mode/Exit-only muting
mode/Position detection muting mode