5-3-3. Standalone F3SG-RE with Y-Joint Plug/Socket
Connector
When using the reduced wiring connector system, the Operating Range Selection is fixed to Long Mode.
Wrong wiring causes the F3SG-RE to go to the Lockout state due to Operating Range Selection Setting error. Make sure
that the cables are properly wired to the connector, referring to 4-5-4-3. Reduced Wiring Connector System.
XS5W-D42 - 81-
Beam state
F39-GCNY1
XS5F-D42 - 80-
IN1
IN2
Safety
Controller *1*2
Unblocked
Blocked
OSSD
Input/Output Circuit and Applications
+24V DC
Power supply
0V
*1. Refer to 5-4. Connectable Safety Control Units
for more information.
*2. The safety controller and the F3SG-RE must
share the power supply or be connected to the
common terminal of the power supply.
E
F3SG-R
201
User's Manual