2-22. Designated Beam Output

F3SG-RA Series
F3SG-RE Series
2-22-1. Overview
This function allows information on unblocked/blocked states of a given beam to be output.
Example:
• To turn a Lamp ON when a specified beam of F3SG-RA is blocked
• To output, from the auxiliary output, a signal of information on a specified beam being unblocked
If one or more specified beams are blocked or unblocked, the information on the beam state can be
provided as an auxiliary output or indication of Lamp.
Operation Example
Designated beam state: Dark-ON
Safety output ON
Designated beam output OFF
Figure 1
Beam state
(Designated beam)
Beam state
(Other than designated beam)
Designated beam output
The Designated Beam Output is not available for the F3SG-RE.
2-22-2. Factory Default Setting
The factory default setting is Designated Beam Output as Disable.
X
Designated
beam
Designated
beam
Safety output OFF
Designated beam output ON
Unblocked
Blocked
Unblocked
Blocked
ON
OFF
ON
OSSD
OFF
System Operation and Functions
Designated beam output OFF
Figure 2
Safety output OFF
Figure 3
F3SG-R
User's Manual