R
Reduced resolution
Reset
Response time adjustment
Response time from ON to OFF
Restart interlock
S
Safety output (OSSD)
Safety output information
SD Manager 2
Secondary sensor
SELV
Setting recovery
Setting state
Standard muting mode
Start interlock
F3SG-R
230
User's Manual
Term
Protected Extra Low Voltage. A grounded circuit separated by double insulation
or equivalent from hazardous voltage. It does not generate voltage that
exceeds ELV under normal conditions and under single-fault conditions.
Normally, protection against direct contact is required.
Function to select the safety output type between PNP and NPN.
Mode that enables the Muting function according to the position of a hazardous
source such as a robot arm, using heterogeneous redundant inputs.
Function to display the period of time when the F3SG-RA is energized, starting
from when the power-on time was last reset until the present time.
Function to reset the power-on time of the F3SG-RA to 0. In the case of
cascade connection, the power-on time can be reset for each cascaded
segment of the F3SG-RA.
When the power-on time exceeds this value, an output is signaled to the
Auxiliary output or Lamp. To signal the information, the Power-On Time
information must be assigned to an output destination.
One of the Interlock reset functions. Interlock state can be released only in the
sequence that the operator operates the Pre-reset switch installed in the
hazardous zone and leave the hazardous zone, and then operates the Reset
switch outside the hazardous zone.
The F3SG-RA under this state is allowed to be blocked after the input of the Pre-
Reset signal is ensured. When the number of times the F3SG-RA is blocked is set
to infinite, the F3SG-RA stays in this state until the Reset input signal is received.
Name used for the F3SG-RA to be connected nearest the power supply, when
in cascade connection.
Function to change the size of the object resolution so that an object of the size
between 1 and 3 beams has no effect.
Function to release the Interlock state or Lockout state.
Function to change the response time so that the Safety outputs can hardly be
turned OFF due to accidental interruption by an environmental factor.
Period of time from when the F3SG-R is blocked until the Safety outputs are
turned from ON to OFF.
Function to turn the Safety outputs to the OFF state when the F3SG-RA is
blocked and keep this state until a reset signal is received.
Output to be turned to the ON state when safety is ensured. This can be used
for safety applications.
Information to be signaled to the Auxiliary output or Lamp when the Safety
outputs are in the ON state. To signal the information, the Safety output
information must be assigned to an output destination.
Setting software that is used as the Configuration Tool for the F3SG-RA. It
allows the user to make settings to or monitor the operation of the F3SG-RA
when the F3SG-RA is connected to the PC via the Interface Unit or Bluetooth
Communication Unit.
Name used for other segments of F3SG-RA's than the primary sensor, when in
cascade connection.
Safety Extra Low Voltage. An ungrounded circuit separated by double
insulation or equivalent from hazardous voltage. It does not generate voltage
that exceeds ELV under normal conditions and under single-fault conditions. If
the nominal voltage exceeds 25 VAC or 60 VDC, protection against direct
contact is required.
Function to restore the factory settings of the F3SG-RA.
Status of the F3SG-RA when settings are being performed with the
Configuration Tool. In this state, the Safety outputs are in the OFF state.
Muting mode to be used for such an application where a muting sensor is
positioned on both sides of the F3SG-RA. The factory default setting is this
mode.
Function to turn the Safety outputs to the OFF state at power-on or recovery
from power failure and keep this state until a reset signal is received.
Description
®