Omron F3SG series User Manual page 239

Safety light curtain
Hide thumbs Also See for F3SG series:
Table of Contents

Advertisement

Description
Cap error
Other sensor error
Blanking monitoring error
Cascading configuration error
External device monitoring error
Safety output error
Communication error
DIP Switch setting error
Error code
4F
A cap may be detached. Attach the cap properly.
38
Other sensor being cascaded caused an error. Check the indicator of the
sensor.
EC
An error is detected by the fixed blanking monitoring function or the floating
blanking monitoring function.
See Chapter 2 "Fixed Blanking" or "Floating Blanking" to solve th e problem.
2-14. Fixed Blanking
2-15. Floating Blanking
39, 3A, 3B
The cascading cable may be short-circuited, broken, or disconnected. Check
that the cascading cable should be tightly connected. If the cascading cable is
broken, replace it.
The number of connected sensors or beams may have exceeded the
maximum value due to cascading.
Check the configuration.
52
Relay may be welded.
Replace the relay.
The relay and the Reset line may not be properly wired.
Check the wiring with the relay.
Chapter 4 Wiring/Installation
The relay response time may be exceeding the allowable delay time.
Change the allowable delay time or replace the relay with one that has an
appropriate response time.
2-10. External Device Monitoring (EDM)
Chapter 4 Wiring/Installation
60, 6B, 6C
Safety output lines may be short-circuited to each other or another signal line
may be short-circuited to the safety output line.
Wire the safety output lines properly.
Chapter 4 Wiring/Installation
30, 31, 32
The communication line or other wiring may be broken or short-circuited.
Check the Cascading or extension cables.
If the wiring is extended with cables other than specified, the cables used for
extension may not have performance equivalent or greater than the specified
cables. Use cables with the same performance or more than the specified
cables.
Chapter 4 Wiring/Installation
E7, E8
A DIP Switch setting may have been changed during operation.
Check if a DIP Switch setting was changed or not.
Settings of two DIP Switches of a receiver may be unmatched.
Check if two DIP Switches of a receiver are matched.
Cause and measures
Appendix
E
F3SG-R
215
User's Manual

Advertisement

Table of Contents
loading

Table of Contents