Glossary

Term
Allowable delay time
A
Auxiliary output
Basic system
B
D
Detection capability
Effective aperture angle
(EAA)
E
External device
monitoring
External test
I
Interlock
Lockout
L
Lower beams
M
Muting
Output operation mode
O
Override
PELV
P
Primary sensor
Reset
R
Response time from ON
to OFF
Safety output (OSSD)
Secondary sensor
SELV
S
V
Vs
The allowable amount of time from when a state of the safety output changes until a state of the external
device monitoring input changes. The F3SJ-B enters lockout if this time is exceeded.
Basic type (basic system) gives inverted signal of safety output, and Basic type (muting system) gives
ON output at muting/override.
Basic system indicates the F3SJ-B with its default factory settings. The basic system provides basic
safety light curtain functions. Most functions can be used without performing additional configuration.
Minimum size of an object that can be detected in the protective height of the F3SJ-B.
Range of angles for which the F3SJ-B can operate.
Function that detects malfunctions, such as welding, in external relays (or contactors) that control the
hazardous zone of a machine, by monitoring the operation of N.C. contacts.
Function that stops emission at any time to check that the safety output is being properly turned OFF.
Function that holds the safety outputs to OFF until safety is ensured and a reset input is applied.
Function that holds safety output OFF when an error is detected by the F3SJ-B.
Indicate beams on F3SJ-B's power supply end.
Function that temporarily disables the safety function of the F3SJ-B, keeping the safety output ON even
if beams are being blocked.
A state of signal sent from the safety output or auxiliary output.
Function that turns the safety output ON when the muting function is not working.
Stands for Protected Extra Low Voltage.
A grounded circuit separated by double insulation or equivalent from hazardous voltage, and does not
generate voltage that exceeds ELV under normal conditions and under single-fault conditions. Normally,
protection for direct contact is required.
Name of the F3SJ-B connected nearest the power supply when series-connected.
Releases the interlock state/lockout state.
Time period from when the F3SJ-B is blocked until the safety output turns from ON to OFF.
The sensor outputs +24 V when it is unblocked. Safety output can be used for safety applications.
Name used for F3SJ-B other than the primary sensor, when series-connected.
Stands for Safety Extra Low Voltage.
An ungrounded circuit separated by double insulation or equivalent from hazardous voltage, and does
not generate voltage that exceeds ELV under normal conditions and under single-fault conditions. If the
nominal voltage exceeds 25 VAC or 60 VDC, protection for direct contact is required.
Voltage value in your usage environment.
Description
Appendix
E
F3SJ-B
97
User's Manual