3.
Securely tighten screws to fix the Top/Bottom Adjustable Bracket to the mounting position of the wall
surface. (Fig. 3)
One screw at upper and lower positions, respectively, is sufficient to fix the F3SG-R to the wall surface. Screws to mount
the brackets to the wall are not included.
4.
Power the F3SG-R on to perform beam alignment.
Move the emitter from side to side (Fig. 4) to align it to a center position where the Stable-state
indicator (STB, green) of the receiver is illuminated while checking the state of the top and bottom
beams with the Top-beam-state indicator (TOP, blue) and Bottom-beam-state indicator (BTM, blue) of
the receiver. (Fig. 5)
Next, move the receiver from side to side to align it to a center position where the Stable-state indicator
(STB, green) of the receiver is illuminated while checking the state of the top and bottom beams with
the Top-beam-state indicator (TOP, blue) and Bottom-beam-state indicator (BTM, blue) of the receiver.
The angle adjustment range of the Top/Bottom Adjustable Brackets is ±22.5°.
F3SG-R
160
User's Manual
<Backside mounting>
Fix the Top/Bottom
Adjustable Bracket to the
wall surface with screws
Fix the Top/Bottom
Adjustable Bracket to the
wall surface with screws
Fig. 4
<Side mounting>
Fig. 3
<Emitter>
<Receiver>
Fig. 5
TOP(Blue)
STB(Green)
BTM(Blue)