CHAPTER 2: MODBUS COMMUNICATION
Products
Address Register name
"
5F53
Frequency Out-Of-Band Accumulator
Target Messages Enable
"
5F54
Frequency Out-Of-Band Accumulator Time
Limit Array (7 items)
"
5F5B
Frequency Out-Of-Band Accumulator Time
Preset Array (7 items)
"
5F62
Frequency Out-Of-Band Accumulator
Upper Frequency Array (7 items)
Setting Groups (Read/Write Setting)
All except C30
5F70
Setting Group for Modbus Comms (0
means group 1)
"
5F71
Setting Groups Block
"
5F73
FlexLogic Operands to Activate Groups 2
through 6 (5 items)
"
5F7D
Setting Group Function
"
5F7E
Setting Group Events
Setting Groups (Read Only)
All except C30
5F7F
Current Setting Group
Setting Group Names (Read/Write Setting)
All except C30
5F8C
Setting Group 1 Name
"
5F94
Setting Group 2 Name
"
5F9C
Setting Group 3 Name
"
5FA4
Setting Group 4 Name
"
5FAC
Setting Group 5 Name
"
5FB4
Setting Group 6 Name
Current Differential 87L (Read/Write Grouped Setting)
L30, L90
6000
87L Current Differential Function
"
6001
87L Current Differential Block
"
6003
87L Current Differential Signal Source 1
"
6004
87L Minimum Phase Current Sensitivity
"
6005
87L Current Differential Tap Setting
"
6006
87L Current Differential Phase Percent
Restraint 1
"
6007
87L Current Differential Phase Percent
Restraint 2
"
6008
87L Current Differential Phase Dual Slope
Breakpoint
"
6009
87L Current Differential Ground Function
"
600A
87L Current Differential Ground Pickup
"
600B
87L Current Differential Ground Restraint
"
600C
87L Current Differential Ground Delay
"
600D
87L Current Differential Key DTT
"
600E
87L Current Differential External Key DTT
"
6010
87L Current Differential Target
"
6011
87L Current Differential Event
"
6012
87L Current Differential Tap 2 Setting
L90
6013
87L Current Differential Signal Source 2
"
6014
87L Current Differential Signal Source 3
"
6015
87L Current Differential Signal Source 4
UR FAMILY – COMMUNICATIONS GUIDE
Range
Units
Step
0 to 2
---
1
1 to 65535
sec
1
0 to 65535
sec
1
20 to 70
Hz
0.01
0 to 5
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 1
---
1
0 to 1
---
1
0 to 5
---
1
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
0 to 1
---
1
0 to 4294967295
---
1
0 to 5
---
1
0.1 to 4
pu
0.01
0.2 to 5
---
0.01
1 to 50
%
1
1 to 70
%
1
0 to 20
pu
0.1
0 to 1
---
1
0.05 to 1
pu
0.01
1 to 50
%
1
0 to 5
seconds 0.01
0 to 1
---
1
0 to 4294967295
---
1
0 to 2
---
1
0 to 1
---
1
0.2 to 5
---
0.01
0 to 6
---
1
0 to 6
---
1
0 to 6
---
1
MEMORY MAP
Format
Default
F109
0 (Self-reset)
F001
200
F001
0
F001
6000
F001
0
F300
0
F300
0
F102
0 (Disabled)
F102
0 (Disabled)
F001
0
F203
(none)
F203
(none)
F203
(none)
F203
(none)
F203
(none)
F203
(none)
F102
0 (Disabled)
F300
0
F167
0 (SRC 1)
F001
20
F001
100
F001
30
F001
50
F001
10
F102
0 (Disabled)
F001
10
F001
25
F001
10
F102
1 (Enabled)
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F001
100
F211
0 (None)
F211
0 (None)
F211
0 (None)
2-77