CHAPTER 2: MODBUS COMMUNICATION
Products
Address Register name
"
6429
Stator Differential Events
"
642A
Stator Differential Line End Source
"
642B
Stator Differential Neutral End Source
Negative Sequence Overvoltage (Read/Write Grouped Setting) (3 Modules)
C70, D30, D60,
6440
Negative Sequence Overvoltage 1 Function 0 to 1
F60, G30, G60,
L30, L60, M60,
T60
"
6441
Negative Sequence Overvoltage 1 Source
"
6442
Negative Sequence Overvoltage 1 Pickup
"
6443
Negative Sequence Overvoltage 1 Pickup
Delay
"
6444
Negative Sequence Overvoltage 1 Reset
Delay
"
6445
Negative Sequence Overvoltage 1 Block
"
6447
Negative Sequence Overvoltage 1 Target
"
6448
Negative Sequence Overvoltage 1 Events
"
6449
...Repeated for Negative Sequence
Overvoltage 2
"
6452
...Repeated for Negative Sequence
Overvoltage 3
Overfrequency (Read/Write Setting) (4 Modules)
C60, D60, F60,
6470
Overfrequency 1 Function
G30, G60, L90,
M60, N60, T60
"
6471
Overfrequency 1 Block
"
6473
Overfrequency 1 Source
"
6474
Overfrequency 1 Pickup
"
6475
Overfrequency 1 Pickup Delay
"
6476
Overfrequency 1 Reset Delay
"
6477
Overfrequency 1 Target
"
6478
Overfrequency 1 Events
"
6479
Reserved (4 items)
"
647D
...Repeated for Overfrequency 2
"
648A
...Repeated for Overfrequency 3
"
6497
...Repeated for Overfrequency 4
Bus Configuration (Read/Write Setting) (2 Modules)
B30
64B0
Bus Zone 1A Source (6 items 1A to 1F)
"
64B6
Bus Zone 1A Status (6 items 1A to 1F)
"
64C2
...Repeated for Bus Zone 2
Bus Differential (Read/Write Grouped Setting) (2 or 6 Modules)
B30, B90
64E0
Bus Zone 1 Function
"
64E1
Bus Zone 1 Pickup
"
64E2
Bus Zone 1 Low Slope
"
64E3
Bus Zone 1 Low Breakpoint
"
64E4
Bus Zone 1 High Slope
"
64E5
Bus Zone 1 High Breakpoint
"
64E6
Bus Zone 1 High Set
"
64E7
Bus Zone 1 Seal In
"
64E8
Bus Zone 1 Block
UR FAMILY – COMMUNICATIONS GUIDE
Range
Units
Step
0 to 1
---
1
0 to 5
---
1
0 to 5
---
1
---
1
0 to 5
---
1
0.004 to 1.25
pu
0.001 F001
0 to 600
s
0.01
0 to 600
s
0.01
0 to 4294967295
---
1
0 to 2
---
1
0 to 1
---
1
0 to 1
---
1
0 to 4294967295
---
1
0 to 5
---
1
20 to 65
Hz
0.01
0 to 65.535
s
0.001 F001
0 to 65.535
s
0.001 F001
0 to 2
---
1
0 to 1
---
1
0 to 1
---
1
0 to 5
---
1
0 to 4294967295
---
1
0 to 1
---
1
0.05 to 6
pu
0.001 F001
15 to 100
%
1
1 to 30
pu
0.01
50 to 100
%
1
1 to 30
pu
0.01
0.1 to 99.99
pu
0.01
0 to 65.535
s
0.001 F001
0 to 4294967295
---
1
MEMORY MAP
Format
Default
F102
0 (Disabled)
F167
0 (SRC 1)
F167
0 (SRC 1)
F102
0 (Disabled)
F167
0 (SRC 1)
300
F001
50
F001
50
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F102
0 (Disabled)
F300
0
F167
0 (SRC 1)
F001
6050
500
500
F109
0 (Self-reset)
F102
0 (Disabled)
F001
0
F167
0 (SRC 1)
F300
0
F102
0 (Disabled)
100
F001
25
F001
200
F001
60
F001
800
F001
1500
400
F300
0
2-85