CHAPTER 2: MODBUS COMMUNICATION
Products
Address Register name
"
5848
...Repeated for FlexLogic Timer 10
"
5850
...Repeated for FlexLogic Timer 11
"
5858
...Repeated for FlexLogic Timer 12
"
5860
...Repeated for FlexLogic Timer 13
"
5868
...Repeated for FlexLogic Timer 14
"
5870
...Repeated for FlexLogic Timer 15
"
5878
...Repeated for FlexLogic Timer 16
"
5880
...Repeated for FlexLogic Timer 17
"
5888
...Repeated for FlexLogic Timer 18
"
5890
...Repeated for FlexLogic Timer 19
"
5898
...Repeated for FlexLogic Timer 20
"
58A0
...Repeated for FlexLogic Timer 21
"
58A8
...Repeated for FlexLogic Timer 22
"
58B0
...Repeated for FlexLogic Timer 23
"
58B8
...Repeated for FlexLogic Timer 24
"
58C0
...Repeated for FlexLogic Timer 25
"
58C8
...Repeated for FlexLogic Timer 26
"
58D0
...Repeated for FlexLogic Timer 27
"
58D8
...Repeated for FlexLogic Timer 28
"
58E0
...Repeated for FlexLogic Timer 29
"
58E8
...Repeated for FlexLogic Timer 30
"
58F0
...Repeated for FlexLogic Timer 31
"
58F8
...Repeated for FlexLogic Timer 32
Phase Time Overcurrent (Read/Write Grouped Setting) (6 Modules)
B30, C60, C70,
5900
Phase Time Overcurrent 1 Function
D30, D60, F35,
F60, G30, G60,
L30, L60, L90,
M60, N60, T35,
T60
"
5901
Phase Time Overcurrent 1 Signal Source
"
5902
Phase Time Overcurrent 1 Input
"
5903
Phase Time Overcurrent 1 Pickup
"
5904
Phase Time Overcurrent 1 Curve
"
5905
Phase Time Overcurrent 1 Multiplier
"
5906
Phase Time Overcurrent 1 Reset
"
5907
Phase Time Overcurrent 1 Voltage
Restraint
"
5908
Phase TOC 1 Block For Each Phase (3 items) 0 to 4294967295
"
590F
Phase Time Overcurrent 1 Target
"
5910
Phase Time Overcurrent 1 Events
"
5911
Reserved (3 items)
"
5914
...Repeated for Phase Time Overcurrent 2
"
5928
...Repeated for Phase Time Overcurrent 3
"
593C
...Repeated for Phase Time Overcurrent 4
"
5950
...Repeated for Phase Time Overcurrent 5
"
5964
...Repeated for Phase Time Overcurrent 6
UR FAMILY – COMMUNICATIONS GUIDE
Range
Units
Step
0 to 1
---
1
0 to 5
---
1
0 to 1
---
1
0.02 to 30
pu
0.001 F001
0 to 16
---
1
0 to 600
---
0.01
0 to 1
---
1
0 to 1
---
1
---
1
0 to 2
---
1
0 to 1
---
1
0 to 1
---
1
MEMORY MAP
Format
Default
F102
0 (Disabled)
F167
0 (SRC 1)
F122
0 (Phasor)
1000
F103
0 (IEEE Mod
Inv)
F001
100
F104
0
(Instantaneo
us)
F102
0 (Disabled)
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F001
0
2-71
2

Advertisement

Table of Contents
loading

This manual is also suitable for: