GE B30 Communications Manual page 79

Ur family
Hide thumbs Also See for B30:
Table of Contents

Advertisement

CHAPTER 2: MODBUS COMMUNICATION
Products
Address Register name
"
406C
Charging Current Compensation
"
406D
Local Relay ID
"
406E
Maximum Channel Asymmetry
"
406F
Number of Channels
"
4070
Number of Terminals
"
4071
Positive Sequence Reactance
"
4072
Round Trip Time
"
4073
Terminal 1 ID
"
4074
Terminal 2 ID
"
4075
Zero-Sequence Current Removal
"
4076
Zero Sequence Reactance
Remote RTD Communications (Read/Write Setting)
G60, M60, T60
407A
RRTD Slave Address
"
407B
RRTD Baud Rate
Communications (Read/Write Setting)
All
407D
COM2 Selection
"
407E
COM1 Minimum Response Time
"
407F
COM2 Minimum Response Time
"
4080
Modbus Slave Address
"
4083
RS485 Com1 Baud Rate
"
4084
RS485 Com1 Parity
"
4085
RS485 Com2 Baud Rate
"
4086
RS485 Com2 Parity
"
4087
Port 1 IP Address
"
4089
Port 1 IP Subnet Mask
"
408B
Port 1 Gateway IP Address
"
408D
Network Address NSAP
"
4097
Port 1 Link Loss Alert
"
4098
Port 2 Link Loss Alert
"
4099
Port 3 Link Loss Alert
"
409A
DNP Channel 1 Port
"
409B
DNP Channel 2 Port
"
409C
DNP Address
"
409E
DNP Client Addresses (2 items)
"
40A3
TCP Port Number for the Modbus protocol
"
40A4
TCP/UDP Port Number for the DNP Protocol 0 to 65535
"
40A5
TCP Port Number for the HTTP (Web Server)
Protocol
"
40A6
Main UDP Port Number for the TFTP
Protocol
"
40A7
Data Transfer UDP Port Numbers for the
TFTP Protocol (zero means "automatic") (2
items)
"
40A9
DNP Unsolicited Responses Function
"
40AA
DNP Unsolicited Responses Timeout
"
40AB
DNP Unsolicited Responses Maximum
Retries
"
40AC
DNP Unsolicited Responses Destination
Address
UR FAMILY – COMMUNICATIONS GUIDE
Range
Units
Step
0 to 1
---
1
0 to 255
---
1
0 to 10
ms
0.1
1 to 2
---
1
2 to 3
---
1
0.1 to 65.535
kohms
0.001 F001
0 to 10
ms
0.1
0 to 255
---
1
0 to 255
---
1
0 to 1
---
1
0.1 to 65.535
kohms
0.001 F001
1 to 254
---
1
0 to 4
---
1
0 to 3
---
1
0 to 1000
ms
10
0 to 1000
ms
10
1 to 254
---
1
0 to 11
---
1
0 to 2
---
1
0 to 11
---
1
0 to 2
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
---
---
---
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 5
---
1
0 to 5
---
1
0 to 65519
---
1
0 to 4294967295
---
1
0 to 65535
---
1
---
1
0 to 65535
---
1
0 to 65535
---
1
0 to 65535
---
1
0 to 1
---
1
0 to 60
s
1
1 to 255
---
1
0 to 65519
---
1
MEMORY MAP
Format
Default
F102
0 (Disabled)
F001
0
F001
15
F001
1
F001
2
100
F001
15
F001
0
F001
0
F102
0 (Disabled)
100
F001
254
F602
4 (19200)
F601
0 (RS485)
F001
0
F001
0
F001
254
F112
8 (115200)
F113
0 (None)
F112
5 (19200)
F113
2 (Even)
F003
2130706433
F003
4278190080
F003
56554497
F074
0
F102
0 (Disabled)
F102
0 (Disabled)
F102
0 (Disabled)
F177
0 (NONE)
F177
0 (NONE)
F001
1
F003
0
F001
502
F001
20000
F001
80
F001
69
F001
0
F102
0 (Disabled)
F001
5
F001
10
F001
1
2-59
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

D30D60F35F60G30G60 ... Show all

Table of Contents