CHAPTER 3: IEC 61850 COMMUNICATION
Data object
CDC
Semantics
name
InjAmp
MV
Injected current.
SH INJECTION AMPS in amperes.
InjVol
MV
Injected voltage.
INJECTED VOLTAGE in volts.
SH INJECTION VOLTS in volts.
InService
SPS
LED indication - Relay In-service. The LED IN SERVICE operand.
IntermSt1
SPS
Intermediate-status detected.
The BREAKER/SWITCH INTERM operand.
IntrAlm
SPS
Indicates that the current exceeded the maximum interrupting current rating
during the last interruption event.
The BKR ARC 1 MAX OP operand.
IntrAlmDpo
SPS
Inverse of IntrAlm.
The BKR ARC 1 MAX DPO operand.
IrigbFail
SPS
A bad IRIG-B input signal has been detected.
The IRIG-B FAILURE operand.
IsoBlk
ACT
B90 - Indicates that the isolator position is invalid
IsOn
SPS
Indicates the time of day timer is on.
The TIME OF DAY 1 ON operand.
IsoPos
ACT
B90 - Indicates position of isolator. When "On", the related current is included in
differential zone; when "Off", the current is excluded from differential calculations.
LastClrTm
INS
Represents the UTC time of user fault reports last cleared time in seconds elapsed
since 1970/01/01, 00.00.00.
The LAST CLEARED DATE actual value.
LastRptTm
INS
Represents the UTC time of last user fault report generated time in seconds
elapsed since 1970/01/01, 00.00.00.
The LAST REPORT DATE actual value.
LastSqNum
INS
Last sequence number received.
Actual value RxGOOSE1 SqNum.
LatchErr
SPS
A difference is detected between the wanted and actual latch contact state.
The LATCHING OUT ERROR operand.
LeoSt
SPS
Line end open status.
The LINE PICKUP LEO PKP operand.
LivDea
SPS
This data object indicates that live/dead conditions have been met.
The SYNC 1 DEAD S OP operand, which indicates that live/dead conditions have
been met.
LivDeaDpo
SPS
This data object indicates that live/dead conditions have not been met.
The SYNC 1 DEAD S DPO operand, which indicates that live/dead conditions have
not been met.
LivLiv
SPS
This data object indicates that both sources are live, and that angle, frequency,
and voltage difference and range conditions have been met.
The SYNC 1 SYNC OP operand, which indicates that both sources are live, and that
angle, frequency, and voltage difference and range conditions have been met.
LivLivDpo
SPS
This data object indicates that one or both sources are not live, or that angle,
frequency, and voltage difference and range conditions have been met.
The SYNC 1 SYNC DPO operand, which indicates that one or both sources are not
live, or that angle, frequency, and voltage difference and range conditions have
been met.
LivV1
SPS
This data object indicates that V1 is above the LivVal1 setting.
The SYNC 1 V1 ABOVE MIN operand, which indicates that V1 is above the LivVal1
setting.
LoadDev
MV
Indicates the motor load standard deviation at the time of the broken rotor bar
data acquisition stage.
LOAD DEV. AT BRB CALC. in x FLA.
LocCmdAcsOff
SPS
Indicates operations of FlexLogic operand ACCESS LOC CMND OFF
LocCmdAcsOn
SPS
Indicates operations of FlexLogic operand ACCESS LOC CMND ON
LocMod
SPS
Capacitor control in local mode.
The CAP 1 IN LOCAL operand.
UR FAMILY – COMMUNICATIONS GUIDE
MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
Used in logical nodes...
SubHaPHIZ
FldGnd0PHIZ, SubHaPHIZ
LEDsIHMI
BkrΘXCBR, DiscΘXSWI,
GGIO3
CBArc0SCBR
CBArc0SCBR
LPHD
B_IsoSSWI
TmDayGAPC
B_IsoSSWI
UFlt0RFLO
UFlt0RFLO
LGOS
LPHD
LinPkpPIOC
SynChkRSYN
SynChkRSYN
SynChkRSYN
SynChkRSYN
SynChkRSYN
BknRotSVBR
SecGSAL
SecGSAL
CapCtlGAPC