GE B30 Communications Manual page 280

Ur family
Hide thumbs Also See for B30:
Table of Contents

Advertisement

MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
LNName: B_DifPDIF#
data obj. data attribute
setSrcRef
setSrcCB
3.5.2.7 B90 end fault protection (B_Efp)
This element is instantiated in the following products: B90.
Table 3-26: B90 end fault protection data objects
LNName: B_EfpPIOC#
data obj. data attribute
Str
general
dirGeneral
3
Op
general
Dpo
stVal
InRefγ1
setSrcRef
setSrcCB
InRefγ2
setSrcRef
setSrcCB
BlkRefγ
setSrcRef
setSrcCB
3.5.2.8 B90 instantaneous overcurrent (B_Ioc)
This element is instantiated in the following products: B90.
Table 3-27: B90 instantaneous overcurrent data objects
LNName: B_IocPIOC#
data obj. data attribute
Str
general
dirGeneral
Op
general
Dpo
stVal
BlkRefγ
setSrcRef
setSrcCB
3.5.2.9 B90 time overcurrent (B_Toc)
This element is instantiated in the following products: B90.
3-42
LDevice inst: Prot
UR element: B90 Bus zone # differential element function
Type
FC UR Name
ObjectReference SP
BUS ZONE #τ STATUS setting
ObjectReference SP
LDevice inst: Prot
UR element: B90 End fault protection element # function
Type
FC UR Name
ACD
BOOLEAN
ST
EFP # PKP
ENUMERATED
ST
ACT
BOOLEAN
ST
EFP # OP
SPS
BOOLEAN
ST
EFP # DPO
ORG
ObjectReference SP
EFP# BREAKER OPEN for group
γ.
ObjectReference SP
ORG
ObjectReference SP
EFP# MANUAL CLOSE for group
γ.
ObjectReference SP
ORG
ObjectReference SP
EFP# BLOCK for group γ.
ObjectReference SP
LDevice inst: Prot
UR element: B90 Instantaneous Overcurrent element #
Type
FC UR Name
ACD
BOOLEAN
ST
IOC # PKP
ENUMERATED
ST
ACT
BOOLEAN
ST
IOC # OP
SPS
BOOLEAN
ST
IOC # DPO
ORG
ObjectReference SP
IOC# BLOCK
ObjectReference SP
CHAPTER 3: IEC 61850 COMMUNICATION
Description
reference to the data attribute to input
source GoCB of input if via GOOSE
Description
EFP # PKP operand
0, the code for unknown. It is unknown as
the element is non-directional
EFP # OP operand
EFP # DPO operand, which is the inverse
of EFP PKP
EFP# BREAKER OPEN setting for setting
group γ.
reference to the data attribute to input
source GoCB of input if via GOOSE
EFP# MANUAL CLOSE setting for setting
group γ.
reference to the data attribute to input
source GoCB of input if via GOOSE
EFP# BLOCK setting for setting group γ. R
reference to the data attribute to input
source GoCB of input if via GOOSE
Description
IOC # PKP operand, which indicates that
Op operates when delay expires
0, the code for unknown
IOC # OP operand
IOC # DPO operand
IOC# BLOCK setting for setting group γ
Reference to the data attribute to input R/C
Source GoCB of input if via GOOSE
UR FAMILY – COMMUNICATIONS GUIDE
R/W/C
R/C
R/C
R/W/C
R
R
R
R
R
R
R
R
R/C
R/C
R
R/C
R/C
R/C
R/C
R/W/C
R
R
R
R
R
R
R
R
R/C

Advertisement

Table of Contents
loading

This manual is also suitable for:

D30D60F35F60G30G60 ... Show all

Table of Contents