GE B30 Communications Manual page 448

Ur family
Hide thumbs Also See for B30:
Table of Contents

Advertisement

MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
Data object
CDC
name
FltLoopRis
MV
FltMulti
SPS
FltRis
MV
FltSegment
ENS
FltSLG
SPS
FltVoid
SPS
FrcTrigger
SPC
3
FrstEthFail
SPS
Function1
ENG
FwdOp
SPS
GoDatSetRef
ORG
GoEnaPort1
ENG
GoID
VSG
GndAmp
MV
GndNeutInd
SPS
GndRis
MV
GpsFail1
SPS
GrAct1
SPS
GrdMasterID
VSS
Ha3NV
MV
Ha3ZroV
MV
HiZIOC
ACT
HiZSt
ENS
HzChgRte
MV
HzLedInd
SPS
HzObAccum
MV
IdFail1
SPS
IndFailBeh
ENG
IndPos1
DPS
3-210
Semantics
D30, D60, L60, L90 - The fault loop resistance
Fault indication - Multi phase fault.
The PHASE SELECT MULTI-P operand.
L90 - The fault resistance at the fault point
L90 - Indicates in which segment of the line the fault occurred: 0 = N/A, 1 = LOCAL,
2 = REMOTE 1, 3 = REMOTE 2
Fault indication - single line to ground.
The PHASE SELECT SLG operand.
Fault indication - Fault type not detected.
The PHASE SELECT VOID operand.
Command for the Hi-Z Oscillography Force Trigger
First Ethernet failure.
The FIRST ETHERNET FAIL operand.
Function Enable/Disable setting: 0 = Disabled, 1 = Enabled (note that TISSUE 670
suggests something like this named SetMod)
Fault direction is forward.
The NEG SEQ DIR OC1 FWD operand.
The NTRL DIR OC1 FWD operand.
Expected value of datSet field in messages subscribed to by RxGOOSE#
The setting RxGOOSE1 DatSet.
Enable all GOOSE on Ethernet port setting: 0 = Disabled, 1 = Enabled
Expected value of goID field in messages subscribed to by RxGOOSE#
The setting RxGOOSE1 ID.
Ground current.
The FIELD GROUND CURRENT in amperes.
An LED.
The LED NEUTRAL/GROUND operand.
Ground resistance.
FIELD GROUND RESIST in ohms.
STATOR GND. RESIST in kilo ohms.
GPS failed at terminal corresponding to instance number.
The 87L DIFF GPS 1 FAIL operand.
Setting group corresponding to index is active (not instantiated in C30).
The SETTING GROUP ACT 1 operand.
Grand master ID actual value
Third harmonic component of neutral voltage.
STATOR GND 3RD HARM VN in volts.
Third harmonic component of zero sequence voltage.
STATOR GND 3RD HARM V0 in volts.
Indicates phase instantaneous overcurrent has operated
Represents the status of Hi-Z fault detection function
Frequency rate of change measured value.
FREQUENCY RATE OF CHANGE 1 in Hz/s.
An LED.
The LED FREQUENCY operand.
FREQUENCY OOB BAND 1 ACCUMULATION in percentage (%)
ID check for a peer L30/L90 on the channel has failed.
87L DIFF CH 1 ID FAIL operand, which becomes On when the differential element's
ID check for a peer L30 on channel 1 has failed.
Setting to select the behavior of the RxGOOSE Boolean when the sending device is
offline: 0 = On, 1 = Off, 2 = Latest/On, 3 = Latest/Off
Generic remote DPS input status values: 0 for intermediate-state, 1 for off, 2 for
on, 3 for bad-state.
RxGOOSE DPS1 actual value.
CHAPTER 3: IEC 61850 COMMUNICATION
Used in logical nodes...
FltRFLO
PhSelGAPC
FltRFLO
FltRFLO
PhSelGAPC
PhSelGAPC
HiZPHIZ
LPHD
Master/LLN0
NegDocRDIR, NeuDocRDIR
LGOS
Master/LLN0
LGOS
FldGnd0PHIZ
LEDsIHMI
FldGnd0PHIZ, SubHaPHIZ
LinDfPDIF
Master/LLN0
TmClkLTMS
StatrPHIZ
StatrPHIZ
HiZPHIZ
HiZPHIZ
RteHzPFRC
LEDsIHMI
HzBnd$PTUF
LinDfPDIF
GGIO3
GGIO3
UR FAMILY – COMMUNICATIONS GUIDE

Advertisement

Table of Contents
loading

This manual is also suitable for:

D30D60F35F60G30G60 ... Show all