GE B30 Communications Manual page 379

Ur family
Hide thumbs Also See for B30:
Table of Contents

Advertisement

CHAPTER 3: IEC 61850 COMMUNICATION
LNName: SynChkRSYN#
data obj. data attribute
Type
units.SIUnit
ENUMERATED
units.multiplier
ENUMERATED
db
INT32U
zeroDb
INT32U
BlkRef1
ORG
GEORG
setSrcRef
ObjectReference SP
VISIBLE
STRING255
setSrcCB
ObjectReference SP
VISIBLE
STRING255
cdcNs
VISIBLE
STRING255
cdcName
VISIBLE
STRING255
InRef3
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
3.5.3.24 Thermal overload (ThmOvl)
This element is instantiated in the following products: B30, C60, C70, D30, D60, F35, F60, G30, G60, L30, L60, L90, N60, T35,
T60.
Table 3-162: Thermal overload data objects
LNName: ThmOvlPTTR#
data obj. data attribute
Type
Op
ACT
general
BOOLEAN
Str
ACD
general
BOOLEAN
dirGeneral
ENUMERATED
InRef2
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
BlkRef1
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
3.5.3.25 Three pole autoreclose (Rec3p)
This element is instantiated in the following products: D30, F35, F60, L30.
Table 3-163: Three pole autoreclose data objects
LNName: Rec3pRREC#
data obj. data attribute
Type
ShotCnt
INS
stVal
INT32
AutoRecSt
ENS
UR FAMILY – COMMUNICATIONS GUIDE
LDevice inst: Ctrl
UR element: Synchrocheck element # (ANSI 25)
FC UR Name
CF
SynChkRSYN#.ProjDifDis.db
CF
SYNCHK# BLOCK.
SP
Reference to the ultimate source
of value selected by setting
SYNCHK# BLOCK.
SP
If reference is external to this
IED, mapped to the source's
GOOSE control block, else empty
string
EX
Name of the GE Multilin
namespace at the time of this
firmware release
EX
GEORG
SYNCHK# SYNC CLOSE.
LDevice inst: Ctrl
UR element: THERMAL OVERLOAD PROTECTION # element
FC UR Name
ST
THERMAL PROT # OP
ST
THERMAL PROT # PKP
ST
THERMAL PROT # RESET
THERMAL PROT # BLOCK.
LDevice inst: Ctrl
UR element: Autoreclose element # functions
FC UR Name
ST
AUTORECLOSE# SHOT COUNT
MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
Description
9
0
0
SYNCHK# BLOCK setting.
reference to the data attribute to input
source GoCB of input if via GOOSE
SYNCHK# SYNC CLOSE setting.
reference to the data attribute to input
source GoCB of input if via GOOSE
Description
THERMAL PROT # OP operand
THERMAL PROT # PKP operand
0, the code for unknown.
THERMAL PROT # RESET setting.
reference to the data attribute to input
source GoCB of input if via GOOSE
THERMAL PROT # BLOCK setting.
reference to the data attribute to input
source GoCB of input if via GOOSE
Description
AUTORECLOSE# SHOT COUNT actual
value
Autoreclosing status
R/W/C
R
R
R/W/C
R
R
R
R/C
R/C
R/C
R/C
3
R
R
R
R/C
R
R/C
R
R/W/C
R
R
R
R
R
R
R/C
R/C
R
R/C
R/C
R/W/C
R
R
R
3-141