MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
Data object
CDC
name
Trouble
SPS
Tx1
SPS
TxStop1
SPS
UnA1
SPS
3
UNotPrgm
SPS
UnV
SPS
UpdateTms
ING
UsrPrgmLED1
SPS
V1Src
CMV
V2Src
CMV
VabRMS
MV
VADmd
MV
VAMaxDmdDt
MV
VArDmd
MV
VArMaxDmdDt
MV
VaRMS
MV
Vaux
CMV
VauxRMS
MV
VbcRMS
MV
VbRMS
MV
VcaRMS
MV
VcRMS
MV
VolLoc
CMV
3-218
Semantics
Trouble operand or LED.
The LED TROUBLE operand.
The SH STAT GND TRB OP operand.
Transmit signal.
The DCUB TX1 operand.
The DUTT TX1 operand.
The HYBRID POTT TX1 operand.
The POTT1 TX1 operand.
The PUTT TX1 operand.
Transmit signal stop.
The DIR BLOCK1 TX1 STOP operand.
Undercurrent pickup.
This operand operates when an open pole condition is detected due to
undercurrent in phase A, B, or C.
The OPEN POLE I< phase A/B/C operand.
The Product Setup > Installation > Relay Settings setting is not programmed.
The UNIT NOT PROGRAMMED operand.
Undervoltage pickup.
The LINE PICKUP UV PKP operand.
Periodic update time
LED indication - User Programmable LED status. For enhanced and standard front
panels.
The LED USER 1 operand.
V1 Voltage phasor.
SYNCHROCHECK 1 V1 voltage phasor, in primary volts.
V2 Voltage phasor.
SYNCHROCHECK 1 V2 voltage phasor, in primary volts.
Phase AB Voltage RMS. SRC 1 Phase AB Voltage RMS, in primary Volts.
Apparent power demand in VA.
SRC 1 DMD VA, in primary volt ampere.
Max apparent power demand in VA with associated date/time stamp. The ClcMth
cannot be used for MAX, as the time stamp definition of IEC 61850 is different
from UR.
SRC 1 DMD VA, in primary volt ampere, with associated date, SRC 1 DMD VA DATE.
Reactive power demand in VAR.
SRC 1 DMD VAR, in primary volt ampere reactive.
Max reactive power demand in VAR with associated date/time stamp. The ClcMth
cannot be used for MAX, as the time stamp definition of IEC 61850 is different
from UR.
SRC 1 DMD VAR, in primary volt ampere reactive, with associated date, SRC 1
DMD VAR DATE.
Phase A Voltage RMS.
SRC 1 Phase AG Voltage RMS, in primary volts.
Auxiliary voltage (fourth input in a voltage AC bank).
SRC 1 Auxiliary Voltage phasor, in primary volts.
Auxiliary voltage RMS (fourth input in a voltage AC bank).
SRC 1 Auxiliary Voltage RMS, in primary volts.
Phase BC Voltage RMS.
SRC 1 Phase BC Voltage RMS, in primary Volts.
Phase B Voltage RMS.
SRC 1 Phase BG Voltage RMS, in primary volts.
Phase CA Voltage RMS.
SRC 1 Phase CA Voltage RMS, in primary Volts.
Phase A Voltage RMS.
SRC 1 Phase CG Voltage RMS, in primary volts.
Composite Voltage at the Local Terminal. Local Vcomp phasor, in primary volts.
CHAPTER 3: IEC 61850 COMMUNICATION
Used in logical nodes...
SubHaPHIZ, LEDsIHMI
DCUB_PSCH, DUTT_PSCH,
HPOTT_PSCH, POTT_PSCH,
POTT1_PSCH, PUTT_PSCH
DCB_PSCH, DCB1_PSCH
LinPkpPIOC, OpnPlΘSCBR
LPHD
LinPkpPIOC
Master/LLN0
LEDsIHMI
SynChkRSYN
SynChkRSYN
ACsrcMMXU
DmdMtrMMTR
DmdMtrMMTR
DmdMtrMMTR
DmdMtrMMTR
ACsrcMMXU
ACsrcMMXN
ACsrcMMXN
ACsrcMMXU
ACsrcMMXU
ACsrcMMXU
ACsrcMMXU
VCompMMXU