CHAPTER 3: IEC 61850 COMMUNICATION
LNName: PhCmp2PDIF1
data obj. data attribute
Type
setSrcCB
ObjectReference SP
Op
ACT
general
BOOLEAN
Table 3-89: Phase comparison negative sequence voltage (excluding FDH) data objects
LNName: PhCmp1PTOV1
data obj. data attribute
Type
Str
ACD
general
BOOLEAN
dirGeneral
ENUMERATED
BlkRefγ
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
Table 3-90: Phase comparison negative sequence voltage (for FDH) data objects
LNName: PhCmp2PTOV1
data obj. data attribute
Type
Str
ACD
general
BOOLEAN
dirGeneral
ENUMERATED
Table 3-91: Phase comparison advanced fault detector rate of change of positive sequence current (excluding FDH)
data objects
LNName: PhCmp1FXOT1
data obj. data attribute
Type
BlkRefγ
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
StrVal
ASG
setMag
AnalogueValue
setMag.f
FLOAT32
units
Unit
units.SIUnit
ENUMERATED
units.multiplier
ENUMERATED
minVal
AnalogueValue
minVal.f
FLOAT32
maxVal
AnalogueValue
maxVal.f
FLOAT32
stepSize
AnalogueValue
stepSize.f
FLOAT32
Op
ACT
general
BOOLEAN
UR FAMILY – COMMUNICATIONS GUIDE
LDevice inst: Prot
UR element: 87PC SCHEME specific to FDH element
FC UR Name
ST
87PC FDH OP
LDevice inst: Prot
UR element: Negative Sequence Voltage element (except FDH element
specifics) as a part of Phase comparison function
FC UR Name
ST
87PC V2 FDL OP
ST
NEG SEQ VOL FD BLK setting
LDevice inst: Prot
UR element: Negative Sequence Voltage element specific to FDH element
as a part of Phase comparison function
FC UR Name
ST
87PC V2 FDH OP
ST
LDevice inst: Prot
UR element: RATE OF CHANGE OF POS SEQ CURRENT element (except FDH
element specifics) as a part of Phase comparison function
FC UR Name
POS SEQ di/dt BLK setting
SG
POS SEQ di/dt FDL PICKUP
CF
CF
CF
CF
ST
87PC di1/dt FDL OP
MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
Description
source GoCB of input if via GOOSE
87PC FDH OP operand
Description
87PC V2 FDL OP operand
0, the code for unknown. It is unknown as
the element is non-directional
NEG SEQ VOL FD BLK setting of setting
group γ.
reference to the data attribute to input
source GoCB of input if via GOOSE
Description
87PC V2 FDH OP operand
0, the code for unknown. It is unknown as
the element is non-directional
Description
POS SEQ di/dt BLK setting of setting
group γ.
reference to the data attribute to input
source GoCB of input if via GOOSE
POS SEQ di/dt FDL PICKUP setting
1 is code for dimensionless
0, the code for a multiplier of 1
0.01
5.00
0.01
87PC di1/dt FDL OP operand
R/W/C
R/C
R
R
R/W/C
R
R
R
3
R
R/C
R/C
R/W/C
R
R
R
R/W/C
R
R/C
R/C
R
R
R
R
R
R
R
R
R
R
R
R
R
R