Scl Logging; Overview Of Process - GE B30 Communications Manual

Ur family
Hide thumbs Also See for B30:
Table of Contents

Advertisement

CHAPTER 3: IEC 61850 COMMUNICATION
Part 7 Tissue
Description
743
CCGR.PmpCtl and CCGR.FanCtl
744
LN STMP, EEHealth and EEName
773
Loc, LocKey and LocSta YPSH and YLTC
774
ITCI.LocKey
800
Misspelling in CSYN
802
CCGR and Harmonized control authority
808
Presence condition of ZMOT.DExt and new Dos
831
Setting of ConfRevNum in LGOS
838
Testing in Beh=Blocked
844
MFLK.PhPiMax, MFLK.PhPiLoFil, MFLK.PhPiRoot DEL->WYE
849
Presence conditions re-assessing in case of derived statistical
calculation
877
QVUB -settings should be optional
909
Remove ANCR.ColOpR and ColOpL
920
Resettable Counter is NOT resettable
932
Rename AVCO.SptVol to AVCO.VolSpt
939
Change CDC for ANCR.FixCol
991
LGOS: GoCBRef (as well as LSVS.SvCBRef) should be mandatory
1007
PTRC as fault indicator - Update of description required
1044
TapChg in AVCO
1077
Rename DOnames within LTIM
Table 3-239: Part 8 Tissues
Part 8-1
Description
Tissue
784
Tracking of control (CTS)
817
Fixed-length GOOSE float encoding
834
File dir name length 64
951
Encoding of Owner attribute
1040
More associate error codes
1178
Select Response+ is non-null value
1324
The response- for DeleteNamedVariableList is not defined

3.9 SCL logging

3.9.1 Overview of process

The process of creating a CID file to import into a UR is described in the
As described, the file can be created using EnerVista software or other, third party IEC 61850 configuration software. The
file transfer to the UR can be done by EnerVista or another client using one of the specified protocols. Upon receipt of the
complete CID file, the UR attempts to parse the file, extract the configuration data and settings that it requires, verify the
data, and then apply the data. During the data application process, the UR is taken out of service automatically if required.
When complete, the UR goes back to its previous in-service or out-of-service state.
During this entire process, an internal log file in the UR is updated to provide information and possibly error logs that can
be used to check the outcome of the process. Transfer this log file from the UR and examine it. This happens automatically
if EnerVista is used to import the CID file to the UR.
UR FAMILY – COMMUNICATIONS GUIDE
Implemented by server?
na
Y
na
na
na
na
na
Y
Y
na
na
na
na
Y
na
na
Y
Y
na
na
Implemented by server?
na
na
Y
na
Y
Y
na
Configuring the UR using SCL
SCL LOGGING
section on page 3-18.
3-229
3