Configuring The Ha Devices - AudioCodes Mediant 800B User Manual

Gateway & e-sbc
Hide thumbs Also See for Mediant 800B:
Table of Contents

Advertisement

If the two devices are connected through two (or more) isolated LAN switches (i.e.,
packets from one switch cannot traverse the second switch), configure the mode to
2RX/2TX:
Figure 41-2: Redundancy Mode for Two Isolated Switches
For Geographical HA (both units are located far from each other), 2Rx/1Tx port mode
connected to a port aggregation switch is the recommended option:
Note:
When two LAN switches are used, the LAN switches must be in the same subnet
(i.e., broadcast domain).
To configure Rx/Tx modes of the Ethernet ports, see 'Configuring Ethernet Port
Groups' on page 130

41.1.2 Configuring the HA Devices

To initially configure the two devices comprising the HA system, do the following
procedures listed in chronological order:
1.
Configuring the first device for HA (see 'Step 1: Configure the First Device' on page
751)
2.
Configuring the second device for HA (see 'Step 2: Configure the Second Device' on
page 753)
3.
Activating HA on the devices (see 'Step 3: Initialize HA on the Devices' on page 754)
User's Manual
Figure 41-3: Rx/Tx Mode for Geographical HA