Parameter
Use Gateway Name for
OPTIONS
configure voip > sip-definition
settings > use-gw-name-for-opt
[UseGatewayNameForOptions]
User Name
configure voip > sip-definition
proxy-and-registration > user-
name-4-auth
[UserName]
Password
configure voip > sip-definition
proxy-and-registration >
password-4-auth
[Password]
Cnonce
configure voip > sip-definition
proxy-and-registration > cnonce-
4-auth
[Cnonce]
Challenge Caching Mode
configure voip > sip-
definition settings >
Version 7.2
IP address parameter contains a domain name with port
definition (e.g., ProxyIP = domain.com:5080), the device
performs a regular DNS A-record query. If a specific Transport
Type is defined, a NAPTR query is not performed.
Note:
This functionality can be configured per Proxy Set in the Proxy
Sets table (see 'Configuring Proxy Sets' on page 357).
When enabled, NAPTR/SRV queries are used to discover
Proxy servers even if the parameter DNSQueryType is
disabled.
Determines whether the device uses its IP address or string
name ("gateway name") in keep-alive SIP OPTIONS messages
(host part of the Request-URI). To configure the "gateway name",
use the SIPGatewayName parameter. The device uses the
OPTIONS request as a keep-alive message with its primary and
redundant SIP proxy servers (i.e., the EnableProxyKeepAlive
parameter is set to 1).
[0] No = (Default) Device's IP address is used in keep-alive
OPTIONS messages.
[1] Yes = Device's "gateway name" is used in keep-alive
OPTIONS messages.
[2] Server = Device's IP address is used in the From and To
headers in keep-alive OPTIONS messages.
Defines the username for registration and Basic/Digest
authentication with a Proxy/Registrar server.
By default, no value is defined.
Note:
The parameter is applicable only to the Gateway application.
The parameter is applicable only if single device registration is
used (i.e., the parameter AuthenticationMode is set to
authentication per gateway).
Analog interfaces: Instead of configuring the parameter, the
Authentication table can be used (see Authentication on page
589).
Defines the password for Basic/Digest authentication with a
Proxy/Registrar server. A single password is used for all device
ports.
The default is 'Default_Passwd'.
Note: Analog interfaces: Instead of configuring the parameter, the
Authentication table can be used (see Authentication on page
589).
Defines the Cnonce string used by the SIP server and client to
provide mutual authentication.
The value is free format, i.e., 'Cnonce = 0a4f113b'. The default is
'Default_Cnonce'.
Enables local caching of SIP message authorization challenges
from Proxy servers.
The device sends the first request to the Proxy without
1027