Telephone Keypad Sequence Parameters - AudioCodes Mediant 800B User Manual

Gateway & e-sbc
Hide thumbs Also See for Mediant 800B:
Table of Contents

Advertisement

User's Manual
Parameter
Analog Metering Type
configure voip > interface
fxs-fxo > metering-type
[MeteringType]
Analog TTX Voltage
Level
[AnalogTTXVoltageLevel
]
Charge Codes Table
Charge Codes
configure voip > gateway
analog charge-code
[ChargeCode]
67.11.10

Telephone Keypad Sequence Parameters

The telephony keypad sequence parameters are described in the table below.
Version 7.2
AOC-E. Parsing every AOC-D received and summing the values is
required to obtain the total sum (that is placed in the AOC-E).
(Applicable only to digital interfaces.)
[5] SIP-to-Tel Interworking = Enables IP-to-Tel AOC, using
AudioCodes' proprietary SIP header, AOC. (Applicable only to digital
interfaces.)
Note: The parameter is applicable only to FXS and ISDN Euro trunks for
sending AOC Facility messages (see Advice of Charge Services for Euro
ISDN on page 578).
Defines the metering method for generating pulses (sinusoidal metering
burst frequency) by the FXS port.
[0] 12 KHz sinusoidal bursts (default)
[1] 16 kHz sinusoidal bursts
[2] Polarity Reversal pulses
Note:
For the parameter to take effect, a device reset is required.
The parameter is applicable only to FXS interfaces.
Determines the metering signal/pulse voltage level (TTX).
[0] 0V = 0 Vrms sinusoidal bursts.
[1] 0.5V = (Default) 0.5 Vrms sinusoidal bursts.
[2] 1V = 1 Vrms sinusoidal bursts
Note:
For the parameter to take effect, a device reset is required.
The parameter is applicable only to FXS interfaces.
Defines metering tones and their time intervals that the FXS interface
generates to the Tel side or the Euro ISDN trunk sends in AOC Facility
messages to the PSTN (i.e., PBX).
The format of the ini file table parameter is as follows:
[ChargeCode]
FORMAT ChargeCode_Index = ChargeCode_EndTime1,
ChargeCode_PulseInterval1, ChargeCode_PulsesOnAnswer1,
ChargeCode_EndTime2, ChargeCode_PulseInterval2,
ChargeCode_PulsesOnAnswer2, ChargeCode_EndTime3,
ChargeCode_PulseInterval3, ChargeCode_PulsesOnAnswer3,
ChargeCode_EndTime4, ChargeCode_PulseInterval4,
ChargeCode_PulsesOnAnswer4;
[\ChargeCode]
Note:
To associate a configured Charge Code to an outgoing Tel-to-IP call,
use the Tel-to-IP Routing table.
To configure the Charge Codes table using the Web interface, see
Configuring Charge Codes Table on page 580.