Isdn Parameters - AudioCodes Mediant 800B User Manual

Gateway & e-sbc
Hide thumbs Also See for Mediant 800B:
Table of Contents

Advertisement

Parameter
ressDigits]
MAX Incoming ANI Digits
[CASStateMachineMaxNumOfIncomingANI
Digits]
Collect ANI
[CASStateMachineCollectANI]
Digit Signaling System
[CASStateMachineDigitSignalingSystem]
67.11.6.4

ISDN Parameters

The ISDN parameters are described in the table below.
Parameter
ISDN Termination Side
configure voip > interface e1-t1|bri >
isdn-termination-side
[TerminationSide]
[TerminationSide_x]
Enable ignoring ISDN Disconnect
with PI
ign-isdn-disc-w-pi
[KeepISDNCallOnDisconnectWithPI]
User's Manual
digits, the collection of address digits is stopped.
The value must be an integer. The default is -1.
Defines the limitation for the maximum ANI digits that
need to be collected. After reaching this number of
digits, the collection of ANI digits is stopped.
The value must be an integer. The default is -1.
In some cases, when the state machine handles the
ANI collection (not related to MFCR2), you can enable
the state machine to collect ANI or discard ANI.
[0] No = Don't collect ANI.
[1] Yes = Collect ANI.
[-1] Default = Default value.
Defines which Signaling System to use in both
directions (detection\generation).
[0] DTMF = DTMF signaling.
[1] MF = (Default) MF signaling.
[-1] Default = Default value.
Table 67-61: ISDN Parameters
Determines the ISDN termination side.
[0] User side = (Default) ISDN User Termination Equipment
(TE) side.
[1] Network side = ISDN Network Termination (NT) side.
Note: Select 'User side' when the PSTN or PBX side is
configured as 'Network side' and vice versa. If you don't know
the device's ISDN termination side, choose 'User side'. If the
D-channel alarm is indicated, choose 'Network Side'.
The BRI module supports the ITU-T I.430 standard, which
defines the ISDN-BRI layer 1 specification. The BRI and PRI
ports are configured similarly, using the parameter. When an
NT port is active, it drives a 38-V line and sends an INFO1
signal (as defined in ITU-T I.430 Table 4) on the data line to
synchronize to a TE port that might be connected to it. To stop
the voltage and the INFO1 signal on the line, stop the trunk
using the Stop Trunk button.
Same as the description for parameter TerminationSide, but
for a specific trunk ID (where x denotes the Trunk ID and 0 is
the first Trunk).
Enables the device to ignore ISDN Disconnect messages with
PI 1 or 8.
[1] = The call (in connected state) is not released if a Q.931
Disconnect with PI (PI = 1 or 8) message is received during
the call.
1138
Mediant 800B Gateway & E-SBC
Description
Description
Document #: LTRT-10298

Advertisement

Table of Contents
loading

Table of Contents