1
Before restarting BMC with "Turn sub power off" option, remove cables
.
from the port on a 10Gb LAN pass through module which connects to the
related server blade.
After restarting BMC, reinsert cables.
2
Before restarting BMC with "Turn sub power off" option, on the connected
.
Brocade VDX switch execute the "shutdown" command to disable the port
which connects to the 10Gb LAN pass through module.
After restarting BMC, on the Brocade VDX switch execute the "no
shutdown" command to enable previously shutdown port.
If this phenomenon occurs, recover with any of the following operations:
1
Turn off the power of the 10Gb LAN pass through module, then turn the
.
power back on. Do this only once.
2
Turn off the power of the CB500 chassis, then turn the power back on.
.
This would require proper shutdown of all blades before doing this step.
Edit certificate
This feature shows, creates, and imports SSL keys and certificates for a
server blade BMC.
2-62