Enter the Installer Code (default = 1561) to 
3
display the Installer Toolbox.
Press System Configuration and begin "RF 
4
Sensor Programming Steps" on page 30.
Use the installation log sheet to record 
5
programmed options for the system.
6
After setting all the required programming 
values for the sensors and the Control Panel, 
press End, then Exit, to save the changes.
After the Control Panel restarts, press Security 
7
/ Menu / Toolbox, enter the Master User Code 
(default = 1111), press User Management and 
setup the user's codes. Be sure to set a Duress 
Code as User #8. Press Back when finished.
Press Brightness/Volume and set the levels for 
8
the installation.
The volume setting does not affect the volume 
9
of alarm sounds.
10
Press → to view the second toolbox screen.
Press Back Light Timeout and set the display 
11
lighting timeout.
Press Set Date and Set Time and set the 
12
calendar and clock. If the Cell Radio Module is 
installed, the date and time sets automatically.
Press the 
 button to return to the Home 
13
Screen.
After completing all setup and programming, refer 
to the User Guide for details on operating the 
system. Check off the programmed options for the 
system in the User Guide.
Be sure to instruct the subscriber on 
NOTE:
the proper operation of the system, and 
leave the User Guide at the installation 
site for reference.
SIA CP-01 Defaults
Several system programmable options have the 
defaults pre‐set to provide compliance with the 
Security Industry Association CP‐01 Standard. All 
other system settings and functions that are 
required to comply with SIA CP‐01 are permanently 
programmed into the Console and cannot be 
changed. Refer to the table for each programmable 
option that has a required SIA CP‐01 programming 
default.
Programming Question SIA CP‐01 Default Range
Q‐1 Wireless Sensor Dialer Delay 30 Seconds
Q‐2 Wired Sensor Dialer Delay
30 Seconds
Q‐5 Exit Delay
60 Seconds
Q‐6 Entry Delay #1
30 Seconds
Q‐7 Entry Delay #2
45 Seconds
Q‐10 Call Waiting Disable Code No Default Code
Q‐20 Swinger Shutdown Count 2 Trips
Q‐26 Auto Stay
Enabled
Q‐27 Exit Delay Restart
Enabled
Q‐31 Cancel Time
5 Minutes
Q‐32 Cancel Display
Enabled
Q‐35 Abort Window Dialer Delay 30 Seconds
Q‐79 Select Output
Follows Internal Sounder See Q‐78 for Options
©2013 2GIG Technologies Inc. All Rights Reserved.
Programming Navigation
On or Off
On or Off
45‐120 Seconds
30‐240 Seconds
30‐240 Seconds
0‐6 Digits
1‐6 Trips
Enabled Disabled
Enabled or Disabled
6‐254 Minutes
Enabled or Disabled
15 or 45 Seconds
23