Go!Control Wireless Security System | Install Guide
•
Enter four digits for the Central Station #2
account number.
•
The Shift button accesses B, C, D, E, and F
characters.
Q-42 Select remote control phone
(0-3)
DEFAULT: Data and voice (3)
This setting controls remote telephone access to
the system. The data option is for the installer. It
allows access for programming and operating the
system with custom PC downloader software.
The voice option is for the subscriber. It allows the
subscriber to call the system from an off‐site
phone, to get the status of the system, and to
perform remote commands. These commands are
executed by entering touch tones. The status is
reported back via voice prompts. A valid User Code
is required for remote telephone access. The user
will be able to perform the following functions: arm
in any mode, disarm, bypass, get system status, and
turn on or turn off the open collector output.
If voice access is enabled, to connect to the panel,
the subscriber will need to call the telephone
number that the Control Panel is connected to,
wait for one or two rings, then hang up. The
subscriber needs to call again, within 10‐45
seconds. The Control Panel answers the call.
When the panel answers the phone, the user will
be prompted to enter their code. If a valid code is
entered, the system will announce the current
system status. If an invalid code is entered, the
panel will ask for the code again. After two invalid
attempts, the panel will disconnect. After two calls,
with two invalid attempts each, the panel will lock
out. The lock out will last for 30 minutes.
•
The default (3) enables data and voice access.
•
For data only access, select (1).
•
For voice access only, select (2).
•
To disable remote access, select (0).
Remote Control Phone Mode
(0) disabled (no remote control phone)
(1) data only
(2) voice only
(3) data and voice
Telephone Key
Remote Control Phone Mode
1
2
Arm the system in Away Mode
3
Arm the system in Stay Mode
4
48
©2013 2GIG Technologies Inc. All Rights Reserved.
System status report
Disarm the system
Telephone Key
Remote Control Phone Mode
5
6
Turn off the auxiliary output
7
Stop the system status report
8
9
#
Bypass all open sensors and arm system
Remotely arming the system to Away
NOTE:
Mode will not start an Exit Delay or
activate Auto Stay Mode (if enabled).
Q-43 Enter installer code (4 digits)
DEFAULT: 1561
The Installer Code is the code required to enter the
Installer Toolbox.
•
The default for the Installer Code is 1561.
•
To change the Installer Code, enter a new 4‐
digit code.
BE SURE TO WRITE DOWN THE NEW CODE!
NOTE:
The Installer Code must be unique from
any User Codes.
Q-44 Select lock installer
programming (0-2)
DEFAULT: Disabled (0)
The installer programming lockout feature is
provided to prevent takeovers. The Control Panel
can be set to limit an installer's access to
programming questions after a period of 48 hours.
The 48 hour lockout timer starts when the installer
exits system configuration mode. Three options are
available:
•
unlimited full access to programming (no
lockout)
•
limited access to programming after 48 hours
•
no access to programming after 48 hours
The default (0) selects unlimited full access to
programming (no lockout).
To deny access to programming after 48 hours,
select no access to programming (1).
To select limited access to programming after 48
hours, select (2). After the system has run for 48
hours, installer will be able to view, but not change,
the Central Station phone number, Central Station
account number, lock installer programming,
download ID, and default lockout fields.
After the 48 hour lockout timer has locked out the
system, the timer can be reset through the cell
radio or PC downloader by remotely setting this
question Q‐44 to (0) or (2). Setting the option to (0)
or (2) will restart the 48 hour lockout timer.