Go!Control Wireless Security System | Install Guide
Q-50 Select trouble reports to CS
(0-1)
DEFAULT: Enabled (1)
Trouble reports can be sent to the Central Station
when any sensor trouble condition occurs.
•
The default (1) allows reporting sensor trouble
conditions.
•
To not report sensor trouble conditions, select
disabled (0).
NOTE:
This setting does not affect trouble
reports caused by Control Panel
conditions, only trouble reports caused by
sensors.
Q-51 Select manual bypass reports
to CS (0-1)
DEFAULT: Disabled (0)
Manual bypass reports can be sent to the Central
Station when any sensor has been manually
bypassed by the user.
•
The default (0) prevents sending manual
bypass reports.
•
To allow sending manual bypass reports, select
enabled (1).
Q-52 Select AC loss reports to CS
(0-1)
DEFAULT: Enabled (1)
AC power loss reports can be sent to the Central
Station if the Control Panel loses AC power.
•
The default (1) allows AC power loss reports.
•
To turn off AC power loss reports, select
disabled (0).
The AC power will have to be absent
NOTE:
from the Control Panel for the time set by
programming question Q‐38 before the
AC power loss trouble alert
displayed (the default is 10 minutes). If
programming question Q‐39 is enabled,
the actual AC power loss report will occur
at a random time of up to four hours after
the AC power loss trouble alert
displayed.
The Control Panel's AC power icon
NOTE:
displays the power status immediately. A
red "X" over the icon indicates no AC
power.
50
©2013 2GIG Technologies Inc. All Rights Reserved.
Q-53 Select system low battery
reports to CS (0-1)
DEFAULT: Enabled (1)
Low battery reports can be sent to the Central
Station if the Control Panel's battery tests low.
•
•
Q-54 Select RF low battery reports
to CS (0-1)
DEFAULT: Enabled (1)
Sensor low battery reports can be sent to the
Central Station if a sensor battery tests low and
sends a low battery transmission to the Control
Panel.
•
•
Q-55 Select opening reports to CS
(0-1)
DEFAULT: Disabled (0)
Opening reports can be sent to the Central Station
each time the system is disarmed. The user or Key
Fob number is indicated in the opening report.
•
•
Q-56 Select closing reports to CS
(0-1)
DEFAULT: Disabled (0)
Closing reports can be sent to the Central Station
each time the system is armed. The user or key fob
is
number is indicated in the closing report. If Quick
Arming is enabled, User #0 is indicated for the
closing report.
•
•
is
Q-57 Select alarm restore reports
to CS (0-1)
DEFAULT: Disabled (0)
Alarm restore reports can be sent to the Central
Station after an alarm when either the bell timeout
The default (1) allows Control Panel low
battery reports.
To turn off Control Panel low battery reports,
select disabled (0).
The default (1) allows sensor low battery
reports.
To turn off sensor low battery reports, select
disabled (0).
The default (0) prevents opening reports.
To allow opening reports, select enabled (1).
The default (0) prevents closing reports.
To allow closing reports, select enabled (1).