Go!Control Wireless Security System | Install Guide
Q-50 Select trouble reports to CS
(0-1)
DEFAULT: Enabled (1)
Trouble reports can be sent to the Central Station 
when any sensor trouble condition occurs.
The default (1) allows reporting sensor trouble 
conditions.
To not report sensor trouble conditions, select 
disabled (0).
NOTE:
This setting does not affect trouble 
reports caused by Control Panel 
conditions, only trouble reports caused by 
sensors.
Q-51 Select manual bypass reports
to CS (0-1)
DEFAULT: Disabled (0)
Manual bypass reports can be sent to the Central 
Station when any sensor has been manually 
bypassed by the user.
The default (0) prevents sending manual 
bypass reports.
To allow sending manual bypass reports, select 
enabled (1).
Q-52 Select AC loss reports to CS
(0-1)
DEFAULT: Enabled (1)
AC power loss reports can be sent to the Central 
Station if the Control Panel loses AC power.
The default (1) allows AC power loss reports.
To turn off AC power loss reports, select 
disabled (0).
The AC power will have to be absent 
NOTE:
from the Control Panel for the time set by 
programming question Q‐38 before the 
AC power loss trouble alert 
displayed (the default is 10 minutes). If 
programming question Q‐39 is enabled, 
the actual AC power loss report will occur 
at a random time of up to four hours after 
the AC power loss trouble alert 
displayed.
The Control Panel's AC power icon 
NOTE:
displays the power status immediately. A 
red "X" over the icon indicates no AC 
power.
50
©2013 2GIG Technologies Inc. All Rights Reserved.
Q-53 Select system low battery
reports to CS (0-1)
DEFAULT: Enabled (1)
Low battery reports can be sent to the Central 
Station if the Control Panel's battery tests low.
Q-54 Select RF low battery reports
to CS (0-1)
DEFAULT: Enabled (1)
Sensor low battery reports can be sent to the 
Central Station if a sensor battery tests low and 
sends a low battery transmission to the Control 
Panel.
Q-55 Select opening reports to CS
(0-1)
DEFAULT: Disabled (0)
Opening reports can be sent to the Central Station 
each time the system is disarmed. The user or Key 
Fob number is indicated in the opening report.
Q-56 Select closing reports to CS
(0-1)
DEFAULT: Disabled (0)
Closing reports can be sent to the Central Station 
each time the system is armed. The user or key fob 
 is 
number is indicated in the closing report. If Quick 
Arming is enabled, User #0 is indicated for the 
closing report.
 is 
Q-57 Select alarm restore reports
to CS (0-1)
DEFAULT: Disabled (0)
Alarm restore reports can be sent to the Central 
Station after an alarm when either the bell timeout 
The default (1) allows Control Panel low 
battery reports.
To turn off Control Panel low battery reports, 
select disabled (0).
The default (1) allows sensor low battery 
reports.
To turn off sensor low battery reports, select 
disabled (0).
The default (0) prevents opening reports.
To allow opening reports, select enabled (1).
The default (0) prevents closing reports.
To allow closing reports, select enabled (1).