Q-11 Enter CS #1 phone number (0-
25 digits)
DEFAULT: No default
The telephone number for Central Station #1 can
be up to 25 digits.
•
Enter the Central Station #1 telephone
number.
•
You can access the pound and star symbols
using the Shift button. The P button adds a 3‐
second pause to the dialing.
If a second Central Station telephone
NOTE:
number is programmed with question Q‐
41, the Control Panel alternates between
the two Central Station telephone
numbers. After two failed telephone
dialing attempts, the Control Panel
attempts to connect using the Cell Radio
Module if it is installed. If the Cell Radio
Module is not installed, the Control Panel
will make 8 dialing attempts.
Q-12 Enter CS #1 account number
(4 digits)
DEFAULT: No default
The account number for Central Station #1 is
always four digits and can include some alpha
characters.
•
Enter four digits for the Central Station #1
account number.
•
The Shift button accesses B, C, D, E, and F
characters.
Q-13 Select 2-way voice (0-2)
DEFAULT: Stay on line (1)
The Control Panel supports 2‐way voice
communications between the subscriber and the
Central Station operator over the telephone line or
the Cell Radio Module (if installed) after an alarm
has been reported.
•
The default (1) allows 2‐way audio over the
telephone line or cell radio.
•
Selecting (2) allows 2‐way audio over the
telephone line or cell radio during fire and CO
alarms.
•
To turn off the 2‐way audio feature, select
disabled (0).
When the Control Panel connects with the
operator, it will beep once per second (every 6
seconds with a cell radio connection). The beep
alternates between two tones and indicates the
Control Panel Programming Questions
Control Panel is waiting for a session command. If
the operator fails to issue a command within one
minute (three minutes with a cell radio
connection), the call is terminated. Once the
operator presses a command option, the beeps will
stop and a 5‐minute audio session will start (3‐
minute audio session with a cell radio connection).
When 2‐way voice communications have been
established, the Central Station operator can use
the following telephone keys to control the
communications. Each time the operator uses a
command key, the session is extended for five
additional minutes (three minutes with a cell radio
connection). During the last minute of
communications, the system beeps twice every 15
seconds to indicate that time is running out.
•
Pressing 1 enables Talk Mode one‐way
communication from the Central Station to the
Premises and allows the operator to talk.
•
Pressing 2 enables VOX Mode two‐way
communications from the Central Station to
the premises.
•
Pressing 3 enables Listen Mode one‐way
communication from the premises to the
Central Station.
•
Pressing 4 extends the session five minutes
without changing the mode of operation.
•
Pressing 5 causes the audio session to end and
terminates the call.
Q-14 Select silent panic/burglary
listen only
DEFAULT: Enabled (1)
The Control Panel supports audio listen‐in of the
subscriber premises from the Central Station over
the telephone line after a silent panic (police
emergency), silent burglary, or duress alarm has
been reported.
•
The default (1) enables audio listen‐in after a
silent panic, silent burglary, or duress alarm.
•
This option is permanently set and cannot be
disabled.
Q-15 Select dialing type (0-1)
DEFAULT: Touch tone (0)
The digital communicator uses tones or pulses.
•
The default (0) is for touch tone (DTMF)
dialing.
•
For rotary dialing, select pulse (1).