Q-23 Enter radio modem network
failure time (0-255)
DEFAULT: 30 minutes
Cell Radio Module must be installed to 
NOTE:
use this function.
Sets the amount of time required for triggering a 
trouble condition if the system detects that the 
optional cellular radio module has lost its cellular 
connection. (After cellular service has been 
restored for 5 minutes, the trouble condition 
clears.)
The default (30) sets the failure detection time 
at 30 minutes.
To disable radio module failure detection, 
select disabled (0).
To choose a different failure detection time, 
select (1‐255) minutes.
Q-24 Select radio modem network
failure causes trouble (0-1)
DEFAULT: Enabled (1)
Cell Radio Module must be installed to 
NOTE:
use this function.
Selects whether the control panel will sound and 
display trouble if the optional cell radio module has 
lost its cellular connection. The trouble sounder 
can be silenced by the user at the Control Panel 
(cell radio trouble is logged regardless of this 
setting). When the cellular radio module 
connection is restored, the trouble indications 
automatically clear.
The default (1) allows radio module failure 
trouble indications.
To turn off radio module failure trouble 
indications, select disabled (0).
Q-25 Select radio modem network
failure reports (0-1)
DEFAULT: Enabled (1)
Cell Radio Module must be installed to 
NOTE:
use this function.
If the optional cell radio module loses its cellular 
connection, the Control Panel can report the fault 
and restore via land‐line if telephone reporting is 
enabled.
The default (1) allows radio module failure/
restore reporting.
To turn off radio module failure/restore 
reporting, select disabled (0).
Control Panel Programming Questions
Q-26 Select auto stay (0-1)
DEFAULT: Enabled (1) (Required SIA CP-
01 Default)
When auto stay is enabled and the system is armed 
in the Away Mode, if an exit/ entry sensor is not 
violated during the Exit Delay, the system will arm 
in the Stay Mode.
The default (1) enables the auto stay feature.
To turn off the auto stay feature, select 
disabled (0).
The auto stay feature does not switch 
NOTE:
the system to Stay Mode if the system is 
armed to Away Mode using a Key Fob 
remote or remotely armed via telephone, 
mobile app, or computer.
Q-27 Select exit delay restart (0-1)
DEFAULT: Enabled (1) (Required SIA CP-
01 Default)
When Exit Delay restart is enabled, re‐entering the 
premises through an exit/ entry door during the 
Exit Delay will restart the Exit Delay. The restart of 
the Exit Delay will only occur one time; further 
violations of an exit/entry sensor will not extend 
the Exit Delay.
The default (1) enables the Exit Delay restart 
feature.
To turn off the Exit Delay restart feature, select 
disabled (0).
Q-28 Select quick exit (0-1)
DEFAULT: Enabled (1)
The quick exit feature allows the user to start the 
Exit Delay while the system is armed. When this 
feature is enabled, a Quick Exit button appears on 
the Security Screen. Pressing Quick Exit while the 
system is armed allows the user to leave through 
an exit/entry door. After the Exit Delay expires, the 
system will return to being armed in the mode it 
was in before (either Stay or Away Mode).
The default (1) enables the quick exit feature.
To turn off the quick exit feature, select 
disabled (0).