Q-23 Enter radio modem network
failure time (0-255)
DEFAULT: 30 minutes
Cell Radio Module must be installed to
NOTE:
use this function.
Sets the amount of time required for triggering a
trouble condition if the system detects that the
optional cellular radio module has lost its cellular
connection. (After cellular service has been
restored for 5 minutes, the trouble condition
clears.)
•
The default (30) sets the failure detection time
at 30 minutes.
•
To disable radio module failure detection,
select disabled (0).
•
To choose a different failure detection time,
select (1‐255) minutes.
Q-24 Select radio modem network
failure causes trouble (0-1)
DEFAULT: Enabled (1)
Cell Radio Module must be installed to
NOTE:
use this function.
Selects whether the control panel will sound and
display trouble if the optional cell radio module has
lost its cellular connection. The trouble sounder
can be silenced by the user at the Control Panel
(cell radio trouble is logged regardless of this
setting). When the cellular radio module
connection is restored, the trouble indications
automatically clear.
•
The default (1) allows radio module failure
trouble indications.
•
To turn off radio module failure trouble
indications, select disabled (0).
Q-25 Select radio modem network
failure reports (0-1)
DEFAULT: Enabled (1)
Cell Radio Module must be installed to
NOTE:
use this function.
If the optional cell radio module loses its cellular
connection, the Control Panel can report the fault
and restore via land‐line if telephone reporting is
enabled.
•
The default (1) allows radio module failure/
restore reporting.
•
To turn off radio module failure/restore
reporting, select disabled (0).
Control Panel Programming Questions
Q-26 Select auto stay (0-1)
DEFAULT: Enabled (1) (Required SIA CP-
01 Default)
When auto stay is enabled and the system is armed
in the Away Mode, if an exit/ entry sensor is not
violated during the Exit Delay, the system will arm
in the Stay Mode.
•
The default (1) enables the auto stay feature.
•
To turn off the auto stay feature, select
disabled (0).
The auto stay feature does not switch
NOTE:
the system to Stay Mode if the system is
armed to Away Mode using a Key Fob
remote or remotely armed via telephone,
mobile app, or computer.
Q-27 Select exit delay restart (0-1)
DEFAULT: Enabled (1) (Required SIA CP-
01 Default)
When Exit Delay restart is enabled, re‐entering the
premises through an exit/ entry door during the
Exit Delay will restart the Exit Delay. The restart of
the Exit Delay will only occur one time; further
violations of an exit/entry sensor will not extend
the Exit Delay.
•
The default (1) enables the Exit Delay restart
feature.
•
To turn off the Exit Delay restart feature, select
disabled (0).
Q-28 Select quick exit (0-1)
DEFAULT: Enabled (1)
The quick exit feature allows the user to start the
Exit Delay while the system is armed. When this
feature is enabled, a Quick Exit button appears on
the Security Screen. Pressing Quick Exit while the
system is armed allows the user to leave through
an exit/entry door. After the Exit Delay expires, the
system will return to being armed in the mode it
was in before (either Stay or Away Mode).
•
The default (1) enables the quick exit feature.
•
To turn off the quick exit feature, select
disabled (0).
©2013 2GIG Technologies Inc. All Rights Reserved.