Go!Control Wireless Security System | Install Guide
Select wired sensor (#) normal
state
DEFAULT: Not used (0)
The two hardwired loops can be wired for normally 
open (N/O) or normally closed (N/C) contacts, or 
for end‐of‐line (EOL) resistor.
The default (0) disables this wired sensor.
To use this wired sensor, select the way the 
loop is wired:
Wired Sensor Normal State
(0) not used
(1) closed
(2) open
(3) end‐of‐line resistor
Select wired sensor (#) dialer delay
(0-1)
DEFAULT: Enabled (1) (Required SIA CP-
01 Default)
Wired sensors can trigger the communicator 
immediately or after a delay. The delay time is set 
by the abort window dialer delay programming 
question Q‐35 (the default delay is 30 seconds).
The default (1) causes delayed dialing for this 
wired sensor number.
For immediate dialing for this wired sensor 
number, select disabled (0).
NOTE:
This default can be changed without 
affecting SIA CP‐01 compliance.
Construct wired sensor (#) voice
descriptor
DEFAULT: No default
The voice descriptors are the words the Control 
Panel will announce for this wired sensor if this 
wired sensor is programmed for voice 
annunciation. Up to five words are allowed.
Press Insert to place a word from the 
1
vocabulary into the data entry field.
Use the ← or → arrows to scroll through the 
2
words, or enter the word's 3‐digit index 
number (see the System Vocabulary Table.
3
Press Insert again for the next word. Up to five 
words are allowed.
To move between words, press the Fwd and 
4
Back buttons.
To remove a word, press Delete.
5
36
©2013 2GIG Technologies Inc. All Rights Reserved.
Select wired sensor (#) reports
(0-1)
DEFAULT: Enabled (1)
Wired sensors can be programmed to trigger a 
report to the Central Station or not.
The default (1) enables reporting for this wired 
sensor number.
To prevent reporting for this wired sensor 
number, select disabled (0).
                                                                                                                      
Select wired sensor (#) chime (0-5)
DEFAULT: (0) Disabled
Each wired sensor can be set to sound a "ding‐
dong" chime and/or sound its
voice descriptor when the sensor is triggered.
The default (0) disables the chime for this 
wired sensor.
If a chime and/or voice is required for this 
wired sensor, choose one of the other chime 
options:
Wired Sensor Chime
(0) disabled
(1) voice only
(2) ding‐dong with voice #1
(3) ding‐dong #2
(4) ding‐dong with voice #2
(5) ding‐dong #1
(6) ding‐ding
(7) ding‐ding with voice
(8) ding‐dong #3
(9) ding dong with voice #3
(10) chime #1
(11) chime #1 with voice #1
(12) chime #2
(13) chime #2 with voice #2