Control Panel Programming Questions - 2gig Technologies Go Control Install Manual

Hide thumbs Also See for Go Control:
Table of Contents

Advertisement

CONTROL PANEL PROGRAMMING QUESTIONS

Q-5 Enter exit delay, in seconds (45-
120)
DEFAULT: 60 seconds
(Required SIA CP-01 Default)
The Exit Delay can be set from 45 to 120 seconds.
The default (60) sets the Exit Delay to 60 
seconds.
To change the Exit Delay, enter a value from 
(45‐120) seconds.
This default can be changed without 
NOTE:
affecting SIA CP‐01 compliance.
Q-6 Enter entry delay 1, in seconds
(30-240)
DEFAULT: 30 seconds (Required SIA CP-
01 Default)
The Entry Delay #1 can be set from30 to 240 
seconds.
The default (30) sets the Entry Delay #1 to 30 
seconds.
To change the Entry Delay #1, enter a value 
from(30‐240) seconds.
Per SIA CP‐01, the combination of the 
NOTE:
Abort Window Dialer Delay (Q‐35) and 
the Entry Delay (Q‐6 or Q‐7) cannot 
exceed one minute.
Q-7 Enter entry delay 2, in seconds
(30-240)
DEFAULT: 45 seconds (Required SIA CP-
01 Default)
The Entry Delay #2 can be set from30 to 240 
seconds.
The default (45) sets the Entry Delay #2 to 45 
seconds.
To change the Entry Delay #2, enter a value 
from(30‐240) seconds.
Per SIA CP‐01, the combination of the 
NOTE:
Abort Window Dialer Delay (Q‐35) and 
the Entry Delay (Q‐6 or Q‐7) cannot 
exceed one minute.
42
©2013 2GIG Technologies Inc. All Rights Reserved.
Q-8 Select dialer (0-1)
DEFAULT: Disabled (0)
The dialer (digital communicator) can be enabled 
for a monitored system or disabled for a local alarm 
or when the cell radio module is used exclusively 
for reporting.
The default (0) sets the dialer as disabled.
To turn on the dialer, select enabled (1).
If the dialer is disabled with this 
NOTE:
programming question, telephone line 
failure detection is also disabled 
regardless of the setting of the telephone 
fail detection question Q‐63.
Q-9 Enter dialing prefix (0-4 digits)
DEFAULT: No default
Some telephone PBX systems require a dialing 
prefix to acquire a dial tone.
If the telephone system that the Control Panel 
is connected to requires a dialing prefix, enter 
up to four digits.
The Shift button accesses the pound and star 
symbols. The P button adds a 3‐second pause 
to the dialing.
Q-10 Enter call waiting disable code
(0-6 digits)
DEFAULT: No default (Required SIA CP-
01 Default)
If the subscriber's telephone line has call waiting, 
incoming call tones on the line could interfere with 
a communicator report to the Central Station. To 
prevent this, the communicator can send the call 
waiting disable code before making a report.
If call waiting is active on the telephone line, 
enter the call waiting disable code.
The Shift button accesses the pound and star 
symbols. The P button adds a 3‐second pause 
to the dialing.
If the first attempt fails, this code will 
NOTE:
be ignored on the rest of the attempts.