Download Print this page

2gig Technologies 2GIG-CO1-345 Installation Instructions

Advertisement

Quick Links

INSTR,INSTL,2GIG-CO1-345 - P/N: 229921 X4 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500" X 11.000" - SCALE: 1-1 - SIDE 1 of 2
2GIG-CO1-345
WIRELESS
CARBON
MONOXIDE
ALARM
Installation
Instructions
Technical Support
866-670-1591
www.2gig.com
SELECT PROPER LOCATION
Dining
REFER TO SECTION
Kitchen
Room
NUMBER 5 ON THE
Family Room
REAR OF THESE
Living Room
INSTRUCTIONS FOR
IMPORTANT MOUNTING
DETAILS
= Carbon Monoxide
Bedroom
alarm location
FIGURE 1. RECOMMENDED
CO ALARM PLACEMENT FOR
SINGLE FLOOR RESIDENCE
Bedroom
Bedroom
Bedroom
FIGURE 2. RECOMMENDED
CO ALARM PLACEMENT FOR
Kitchen
Living
Garage
MULTI-LEVEL RESIDENCE
Room
= Carbon Monoxide alarm
Basement
location for multi-level
residence
Inside wall location
FIGURE 3. RECOMMENDED
CO ALARM MOUNTING
Height 5' - 6' from floor
LOCATION IS 5 TO 6 FEET
FROM FLOOR
= Carbon Monoxide alarm
mounting location
INSTALL MOUNTING PLATE
SCREW
ANCHORS
FOR WALLBOARD
OR
PLASTIC
SINGLE-GANG
ELECTRICAL BOX
PRINTERS INSTRUCTIONS
PRODUCT DESCRIPTION
The 2GIG-CO1-345 is a carbon monoxide (CO) alarm with a built-in
transmitter designed for use with the 2GIG-CNTRL-345 security system.
The detector gives warning to alert against both the acute and chronic
effects of CO poisoning. When carbon monoxide is detected, the alarm
sounds a loud local alarm. When the local alarm sounds, the built-in
transmitter sends a digitally coded wireless signal to the Control Panel
every 20 seconds until the air has cleared and the detector is restored.
The 2GIG-CO1-345 detector can send four different signals: alarm, test,
low battery, and status.
The local alarm can be silenced once by pressing the TEST/RESET
button. The detector will continue to send an alarm signal every 20
seconds. After 7 minutes, the alarm will sound again if there is still an
unsafe CO concentration level. The reset function can be used only once
for each alarm occurrence.
The Control Panel must be programmed to the detector's serial
number before system testing and operation. Refer to the Control
Panel's instructions for details on programming.
R
The detector is powered by one 3-volt lithium battery. The battery is
CM
supplied with the detector and can power the unit for more than one year.
If the battery voltage drops below a preset level the alarm will sound a
low battery chirp every 45 seconds and a low battery signal will be sent
to the Control Panel.
When the detector reaches the end of its serviceable life (after about 6
years) a permanent trouble condition will occur and cannot be reset.
Maintenance: Occasionally clean the outside casing with a cloth. Ensure
that the holes on the front of the alarm are not blocked with dirt and dust.
Do not paint, and do not use cleaning agents, bleach, or polish on
the detector.
REMOVE MOUNTING PLATE
Bedroom
TWIST MOUNTING
PLATE TO UNLOCK
Bedroom
PROGRAM CONTROL PANEL
REFER TO CONTROL PANEL'S INSTRUCTIONS
TO PREPARE RECEIVER TO ACCEPT THE
DETECTOR'S SERIAL NUMBER
PRESS UNTIL ALARM
BEEPS THEN RELEASE
TEST BUTTON TO
SEND SIGNAL
DETECTOR
A TEST SIGNAL WILL BE SENT A
FEW SECONDS AFTER THE
SWITCH IS RELEASED
ALARM
SOUNDER
TEST/RESET
BUTTON
NORMAL
OPERATION
ALARM
SIGNAL
TROUBLE
SIGNAL
LOW BATTERY
SIGNAL
END-OF-LIFE
SIGNAL
REMOVE BATTERY TAB
REMOVE
BATTERY TAB
TO APPLY
POWER
REMOVE
MOUNTING
3-VOLT LITHIUM BATTERY - TYPES: DURACELL DL123A,
PLATE
PANASONIC CR123A, SANYO CR123A, ADEMCO 466.
AVAILABLE AT LOCAL RETAILERS AND INTERNET
SUPPLIERS. NOTE: USE ONLY THESE SPECIFIC
BATTERY MODELS.
MOUNT ALARM ON PLATE
TWIST CO ALARM CLOCKWISE TO
LOCK ONTO MOUNTING PLATE
CONTROL PANEL
FEATURES
CARBON
MOUNTING
MONOXIDE
PLATE
ALARM
MOUNTING
SCREWS &
ANCHORS
ALARM SIGNALS
GREEN LED FLASHES EVERY 10 SECONDS.
A REPEATING PATTERN OF FOUR SHORT BEEPS AND
5 SECOND SILENCE. THE RED LED WILL FLASH ONCE
PER SECOND.
DETECTOR SELF-TESTS EVERY 10 SECONDS. IF A
FAULT IS DETECTED, RED LED WILL BLINK EVERY
5 SECONDS AND DETECTOR WILL BEEP EVERY
45 SECONDS. IN THIS CONDITION, THE DETECTOR
REQUIRES IMMEDIATE REPLACEMENT.
RED LED BLINKS EVERY 45 SECONDS.
REPLACE THE BATTERY WHEN THIS SIGNAL OCCURS.
RED LED WILL BLINK ONCE EVERY 10 SECONDS AND
DETECTOR WILL BEEP EVERY 45 SECONDS. IN THIS
CONDITION, THE DETECTOR REQUIRES IMMEDIATE
REPLACEMENT.
NOTE: ON POWER-UP THE RED AND
GREEN LEDS WILL BLINK 4 TIMES,
15 SECONDS APART WHILE
THE ALARM INITIALIZES.
ALIGN TAB IN PLATE WITH
NOTCH IN COVER

Advertisement

loading

Summary of Contents for 2gig Technologies 2GIG-CO1-345

  • Page 1: Installation Instructions

    PRINTERS INSTRUCTIONS INSTR,INSTL,2GIG-CO1-345 - P/N: 229921 X4 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - SIDE 1 of 2 PRODUCT DESCRIPTION FEATURES 2GIG-CO1-345 The 2GIG-CO1-345 is a carbon monoxide (CO) alarm with a built-in CARBON transmitter designed for use with the 2GIG-CNTRL-345 security system.
  • Page 2 PRINTERS INSTRUCTIONS INSTR,INSTL,2GIG-CO1-345 - P/N: 229921 X4 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - SIDE 2 of 2 If alarm sounds: WARNING 1 Operate reset/silence button ACTUATION OF YOUR CO ALARM INDICATES THE 2 Call your emergency services fi...