Go!Control Wireless Security System | Install Guide
Q-16 Select police emergency key
(0-2)
DEFAULT: Audible (1)
The Control Panel's panic emergency button action 
can be programmed. The panic emergency button 
is displayed by pressing the 
The default (1) allows the panic emergency 
button to sound an audible alarm.
For silent activation, select silent panic (2).
To disable and not display the panic 
emergency button, select disabled (0).
Setting this programming question for 
NOTE:
silent panic (2) makes the Police button 
on all RF keypads silent also.
Q-17 Select fire emergency key
(0-1)
DEFAULT: Audible (1)
The Control Panel's fire emergency button can be 
enabled or disabled. The fire emergency button is 
displayed by pressing the Control Panel's 
button.
The default (1) allows the fire emergency 
button to sound an audible alarm.
To disable and not display the fire emergency 
button, select disabled (0).
Q-18 Select emergency key (0-1)
DEFAULT: Audible (1)
The Control Panel's emergency button can be 
enabled or disabled. The panel's emergency button 
is displayed by pressing the Control Panel's 
button.
The default (1) allows the emergency button 
to sound an audible alarm.
To disable and not display emergency button, 
select disabled (0).
NOTE:
If all three emergency buttons are 
disabled, pressing the Control Panel's 
button displays a message that the 
emergency buttons are disabled.
Q-19 Select quick arming (0-1)
DEFAULT: Enabled (1)
Quick arming allows the subscriber to arm the 
system without having to enter their User Code. 
(Quick arming reports as User 0 if open/close 
reports are sent.)
The default (1) allows quick arming.
To turn off quick arming, select disabled (0).
44
©2013 2GIG Technologies Inc. All Rights Reserved.
 button.
 
 
 
Q-20 Select swinger shutdown
count (1-6)
DEFAULT: Two trips (2) (Required SIA
CP-01 Default)
An unwanted series of multiple faults (usually 
caused by a bad contact or sensor) is called a 
"swinger." Swinger shutdown sets the maximum 
number of alarms that any sensor or hardwire loop 
can trigger during a single arming period.
CO and smoke detector alarms are not 
NOTE:
limited by the swinger shutdown count. 
Other types of 24‐hour zones are limited 
by the swinger shutdown count.
The default (2) sets the swinger shutdown 
count at two trips.
To change the swinger shutdown count, select 
(1‐6).
NOTE:
This default can be changed without 
affecting SIA CP‐01 compliance.
Q-21 Select siren supervision time
(0-3)
DEFAULT: Disabled (0)
The wiring connection to the external sounder can 
be supervised. If the wiring to the sounder is cut for 
15, 30, or 45 seconds, a bell trouble report can be 
sent to the Central Station.
The default (0) disables external sounder 
supervision.
To supervise the external sounder wiring, 
select:
(1) for 15 seconds
(2) for 30 seconds
(3) for 45 seconds
Q-22 Enter CS lack of usage
notification time (0-255)
DEFAULT: Seven days (7)
Inactivity reports can be sent to the Central Station 
if the system has not been armed for a period of 
days.
The default (7) sets the lack of usage feature at 
seven days.
To change the lack of usage feature duration, 
select (1‐255) days.
To turn off the lack of usage feature, select 
disabled (0).