Go!Control Wireless Security System | Install Guide
Q-16 Select police emergency key
(0-2)
DEFAULT: Audible (1)
The Control Panel's panic emergency button action
can be programmed. The panic emergency button
is displayed by pressing the
•
The default (1) allows the panic emergency
button to sound an audible alarm.
•
For silent activation, select silent panic (2).
•
To disable and not display the panic
emergency button, select disabled (0).
Setting this programming question for
NOTE:
silent panic (2) makes the Police button
on all RF keypads silent also.
Q-17 Select fire emergency key
(0-1)
DEFAULT: Audible (1)
The Control Panel's fire emergency button can be
enabled or disabled. The fire emergency button is
displayed by pressing the Control Panel's
button.
•
The default (1) allows the fire emergency
button to sound an audible alarm.
•
To disable and not display the fire emergency
button, select disabled (0).
Q-18 Select emergency key (0-1)
DEFAULT: Audible (1)
The Control Panel's emergency button can be
enabled or disabled. The panel's emergency button
is displayed by pressing the Control Panel's
button.
•
The default (1) allows the emergency button
to sound an audible alarm.
•
To disable and not display emergency button,
select disabled (0).
NOTE:
If all three emergency buttons are
disabled, pressing the Control Panel's
button displays a message that the
emergency buttons are disabled.
Q-19 Select quick arming (0-1)
DEFAULT: Enabled (1)
Quick arming allows the subscriber to arm the
system without having to enter their User Code.
(Quick arming reports as User 0 if open/close
reports are sent.)
•
The default (1) allows quick arming.
•
To turn off quick arming, select disabled (0).
44
©2013 2GIG Technologies Inc. All Rights Reserved.
button.
Q-20 Select swinger shutdown
count (1-6)
DEFAULT: Two trips (2) (Required SIA
CP-01 Default)
An unwanted series of multiple faults (usually
caused by a bad contact or sensor) is called a
"swinger." Swinger shutdown sets the maximum
number of alarms that any sensor or hardwire loop
can trigger during a single arming period.
CO and smoke detector alarms are not
NOTE:
limited by the swinger shutdown count.
Other types of 24‐hour zones are limited
by the swinger shutdown count.
•
The default (2) sets the swinger shutdown
count at two trips.
•
To change the swinger shutdown count, select
(1‐6).
NOTE:
This default can be changed without
affecting SIA CP‐01 compliance.
Q-21 Select siren supervision time
(0-3)
DEFAULT: Disabled (0)
The wiring connection to the external sounder can
be supervised. If the wiring to the sounder is cut for
15, 30, or 45 seconds, a bell trouble report can be
sent to the Central Station.
•
The default (0) disables external sounder
supervision.
•
To supervise the external sounder wiring,
select:
•
(1) for 15 seconds
•
(2) for 30 seconds
•
(3) for 45 seconds
Q-22 Enter CS lack of usage
notification time (0-255)
DEFAULT: Seven days (7)
Inactivity reports can be sent to the Central Station
if the system has not been armed for a period of
days.
•
The default (7) sets the lack of usage feature at
seven days.
•
To change the lack of usage feature duration,
select (1‐255) days.
•
To turn off the lack of usage feature, select
disabled (0).