Installer Testing - 2gig Technologies Go Control Install Manual

Hide thumbs Also See for Go Control:
Table of Contents

Advertisement

To set the calendar and the clock press Set 
10
Date and Set Time.
On the Set Date screen, use the ↓ and ↑ 
arrows to set the month, day, and year. On the 
Set Time screen, use the ↓ and ↑ arrows to 
set the hours, minutes, and AM/PM. When 
done, press Ok. A confirmation screen 
appears. Verify the time and date, then press 
Ok again.
If the cell radio module is installed and 
11
registered, the date and time is set 
automatically.
To return to the Security Screen, press Back
OR 
To return to the Home Screen, press the 
button.
INSTALLER TESTING
Testing the System
After the installation is complete and the Control 
Panel programming is complete, the system must 
be tested to ensure proper operation.
System testing is performed through the Installer 
Toolbox screen.
1
Press the lower right corner of the Home 
screen.
To access the Installer Toolbox, enter the 
2
Installer Code (default = 1561).
Sounder Disable/Enable
Because testing causes the Control Panel's internal 
and external alarm sounder to activate, an option 
to lower the sounder is available.
1
From the Installer Toolbox Screen, press 
Disable Sounder.
A confirmation screen appears. Press Ok. Four 
2
beeps will sound from the internal sounder, 
and a short siren will sound from the external 
sounder. The external siren will be disabled 
and the internal sounder will be lowered for 
30 minutes.
A second confirmation screen appears to 
3
verify that the test sounds occurred. Press Ok.
While the sounder is disabled, the Sounder 
4
Disable Icon appears on the status bar.
 
The Sounder Disable automatically times out 
5
after 30 minutes, and the sounder 
automatically becomes active again.
To re‐enable the sounder manually, follow these 
steps:
1
From the Installer Toolbox Screen, press 
Enable Sounder.
A confirmation screen appears. Press Ok.
2
Zone Reporting Test
To verify that the Central Station correctly receives 
reports from each zone (sensor type), do the 
following tests:
Inform the Central Station that test signals will 
1
be sent.
2
Trigger a 24‐hour fire sensor (if installed) or 
press the Fire emergency button (if enabled), 
wait about 45 seconds for the report to 
complete, then disarm the Console.
©2013 2GIG Technologies Inc. All Rights Reserved.